Revision 1.1
14
6.
Preventive Maintenance and Quick Check
The MiniFix needs preventive maintenance to perform at its fullest capacity. Lubricate and inspect regularly.
Also check that all details are damaged: Hoses, cables, controls, etc.
REPAIR OR REPLACE IMMEDIATELY FAULTY PARTS
6.1
Maintenance and Care
The following “inspection and maintenance” should be performed at the recommended intervals depending on
operation and amount of cycles or at the time when the unit shows any signs of damage or abuse. Remember
that the secret to a long life of your PALFINGER Liftgate is to maintain it through preventive care.
* Recommended bases for
inspection and maintenance
Depending
on use
Daily
Monthly
Quarterly
cleaning
x
general lubrication of pins and
bushings
x
oil level inspection
x
oil change
x
check hydraulic hoses and pipes for
leaks
x
check controls and connections
x
check pins and pin retaining bolts
x
check batteries and connections
x
check warning labels and other safety
equipment for effectiveness and
visibility
x
visual check for loose or missing parts
and un-usual noise during operation
x
check lock bolts and pins for tightness
x
check complete function of gate
x
check mounting brackets of lift gate to
frame for cracks or damage visually
x
Table 1: Maintenance Schedule
All parts except the chrome-coated piston rods, the push buttons, solenoids valves, foot controls and warning
lights can be cleaned by means of a water jet.
Summary of Contents for MiniFix