Revision 1.1
23
Platform does not tilt or very
unsteadily
after
reaching
the
ground
1. Flow valve R5 or shuttle valve
jam or defective
2. Tilt angle switch B13 is adjusted
incorrect or defective
3. PC-Board is defective
4. Solenoid valve S3 on
tilting Cylinder soiled or
defective
1. Adjust or Replace
2. B13 Sensor is defective or its
tilt angle is incorrectly set
3. Replace
4. Clean or Replace
Platform does not tilt or lift at lifting
mode
1. Operating buttons or switches,
foot or remote control is
defective
1. Replace defective Parts
Platform lifts but does not tilt at
lifting mode
1. Directional valve S5 jams or is
defecive
2. Tilt angle Sensor B16 is
defective
1. Clean or defective
2. Replace
Platform tips further in lifting mode
that presetted
1. Tilt angle sensor B16 is
defective
2. Directional valve S5 jams or
defective
1. Replace
2. Clean or Replace
Platform does not lift, even the
hydraulic unit is running
1. Directional valve S5 jams or is
defective
2. Solenoid valve S1 on
lifting Cylinder is soiled or
defective
3. Suction Filter on pump soiled
4. Platform overloaded
5. Hydraulic pump is defective
6. Electrical motor is defective
7. Shuttle valve soiled or defective
8. Pressure control valve
incorrectly set or defective
1. Clean or Replace
2. Clean or Replace
3. Clean or Replace
4. Reduce load in accordance
with the load table
5. Replace pump
6. Replace motor
7. Clean or Rerplace
8. Reset and lead or Replace
Platform does not close
1. Directional valve S5 jams or
defective
1. Replace defective Parts