Beamed data does not transmit:
•
Confirm that the SPT 1550 terminals are 5” apart, and that
the path between the two devices is clear of obstacles.
When receiving beamed data an out of memory message
appears:
•
Your SPT 1550 terminal requires at least twice the amount of
memory available as the data you are receiving. For exam-
ple, if you are receiving a 30K application, you must have at
least 60K free.
Your SPT 1550 unit does not accept scan input:
•
Verify that the unit is loaded with a scanning application. See
your System Administrator.
•
Check to be sure the bar code symbol is not defaced.
•
Be sure you are within proper scanning range.
•
Be sure the unit is programmed to accept the type of bar
code you are scanning.
•
If you are expecting a beep on a good decode and don’t hear
one, check that the application is set to generate a beep on
good decode.
•
If the scanner stops emitting a laser beam when you press
the trigger, check your battery level. When the battery is low,
the scanner shuts off before the terminal notifies you of the
low battery condition.
Note:
If, after performing these checks, the scanner is still not
reading symbols, contact your distributor or Symbol
Technologies.