this case, the floor boards should not be attached very densely to avoid likely bulging. Leave some
space (1-2 mm) between the floor boards to allow for swelling. But if your climate is warm and dry, you
can install the boards densely because they will become drier and spaces may appear between them.
Storm braces
(NB! Not included in some house option kits!)
Attach the storm braces (if included in
the supplied kit) to the inner sides of
the front (2 units) and back (2 units)
walls with the supplied bolts. It is
important for the logs to be drilled
through in advance. Please keep the
distances indicated in the drawing so
that no problems occur due to wood
swelling or diminishing.
ADVICE
: Make sure that the storm
braces are attached to the apex log
from above and to the middle of the
first full-length wall log from below. If
necessary, shorten the upper ends of
the slats.
Do not turn the screws tightly so wood
can further swell or diminish.
With the house having settled, you
should adjust the attachments so the
wall logs can settle.
Installation of storm braces:
General advice:
Problem:
Gaps appear between the wall logs
Cause:
Additional details are attached to the house that do not allow wood to
swell/diminish.
Solutions:
If the door/window is attached to the wall logs with screws/nails, remove these
screws/nails;
If the storm brace is screwed on too tightly, loosen its attachment;
If (rain water) pipes are installed on the wall, loosen their attachments;
Problem:
The doors and windows become stuck.
Cause:
The house/foundation has settled.
Solution:
Check whether the house is level. Level the foundation joists and walls.
Cause:
The doors and windows have swelled due to moisture.
Solution:
Adjust the door and window hinges; if necessary, plane the door or window narrower.
We wish you total success with the garden house installation and much
joy with this house for many years to come!
Summary of Contents for FR19-2421
Page 5: ...210 4 0 m2 220 190 252 ...
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ... 16 0 ...
Page 13: ......
Page 14: ......
Page 15: ...1900 2200 A B A B EN Laying on concrete slabs not included FR Pose sur dalle béton non inclus ...
Page 17: ...001 x14 007 x28 009 x28 ...
Page 20: ...200 1 2 PR1 x2 PR2 x1 StB1 1 x4 M8x60 x8 Ø5x90 x6 200 Ø8 1 Ø8 1 Ø3 1 58 20 M8x60 M8x60 Ø5x90 ...
Page 21: ...RB1 1 x48 Ø2 5x50 x200 ...
Page 22: ...YPapp 1 RB1 1 RE1 1 Ø3x30 1 2 RE1 1 x2 x3 Ø2x16 x120 Ø3x30 x14 YPapp 1 ...
Page 23: ...1 2 Ø2 1 FaB3 1 x4 WB1 1 x4 Dia 1 x2 Ø3 5x40 x44 FaB3 1 WB1 1 Dia 1 ...
Page 25: ...Sla1 250 300 Ø2 1 Ø4x16 Ø4x16 Ø3 5x25 Ø10 20mm Ø10 20mm 1 2 5 5 5 Ø3 5x25 Ø3 5x25 Ø2 1 ...
Page 26: ...30 ...