background image

3

General Work Products LLC | 6000 Jefferson Hwy | Harahan, LA 70123

www.PalmerSafetyUS.com

•Fall Protection •Training •Netting •PPE

Worker Definitions

NOTE:

 It is important to know the definition of those who work near or who may be exposed to fall hazards.

Qualified Person:

 A person with accreditation for this position who has sufficient experience or standing in their industry. 

They are responsible for reviewing the effectiveness of fall prevention and rescue procedures.

Competent Person:

 A fall safety coordinator is a person who has been trained to manage all aspects of a company’s fall 

safety program. This includes the actual regulation, the management thereof and its application. A person tasked with 

identifying existing or foreseeable hazards. They have the power to temporarily stop work to address any concerns they 

might have.

Authorized Person:

 An employee who’s area of responsibility includes areas where potential or existing fall hazards 

exist. These employees need to be trained to understand what it takes to work safely around these hazards.

Qualified or Competent person on jobsite is responsible for training and inspection of 2-Way Standing Seam 

Anchor. Please contact your local Palmer Safety Specialist if you have questions or need training. We can provide 

training on the jobsite.

Applications

WARNING:

 Using the equipment in ways other than its intended purpose may result in severe injury or death. Maximum 

1 attachment per connection point. 

Fall Arrest:

 The 2-Way Standing Seam Anchor, which can be used in Personal Fall Arrest (PFAS) applications, is for use 

by only 1 person and must be used with the appropriate supporting structure. The supporting structure must also withstand 

loads applied in the advised directions of at least 5000 lbs. Maximum freefall height is 6 feet, or up to 12 feet when in 

combination with a harness that has been tested for such use. The D-ring needs to be in the dorsal position.

Restraint:

 The 2-Way Standing Seam Anchor can be utilized in Restraint systems. Restraints are used to ensure workers 

do not get too close to the edge of any fall hazards. Only 1 person can use the 2-Way Standing Seam Anchor at a time 

when working in restraint. Make sure to account for the full length of the lanyard or SRL that you plan on using. The 

structure must be guaranteed to withstand loads that are at least 1,000 lbs. in every direction. No item shall be allowed to 

fall without restraint. Restraint systems can only be used on surfaces where slopes are up 4/12.

D-rings that can used: Dorsal, Chest, Side, Shoulder.

TOTAL user weight capacity range (including person, clothing, tools, and equipment) is 130-310 lbs.

Summary of Contents for ANCHOR2WAYSEAM

Page 1: ...Fall Protection Training Netting PPE INSTRUCTION MANUAL 2 WAYSTANDINGSEAMANCHOR These Instructions Apply to the Following Model s ANCHOR2WAYSEAM ANCHOR2WAYSEAMEX...

Page 2: ...rotection 2 Way Standing Seam Anchor This manual must be read and understood in its entirety whereas any specified training course on fall protection can be utilized to provide the necessary knowledge...

Page 3: ...t if you have questions or need training We can provide training on the jobsite Applications WARNING Using the equipment in ways other than its intended purpose may result in severe injury or death Ma...

Page 4: ...ermit a swing fall if injury could occur Swing falls will significantly increase the clearance required when a self retracting lifeline or other variable length connecting subsystem is used Compatibil...

Page 5: ...lowable working zones required to reduce risk of swing falls and improper side loading ALWAYS adhere to information specified by chart Anchor Distance From Leading Edge Y Working Distance Along Roof E...

Page 6: ...r Part No ANCHORW2AYSEAMEX Rev B Made in China XX XXXX XXXXXXXXXXXXXXXX 6000 Jefferson Highway Harahan LA 70123 504 733 1808 PalmerSafetyUS com BEFORE EACH USE Inspect for any deformities unusual wear...

Page 7: ...oof of at least 24 gauge thickness Installation and Use 1 Install on a fully seamed panel and must be installed over a clip that is bolted or screwed down 2 At a minimum 2 Way Standing Seam Anchor mus...

Page 8: ...ding Seam Anchor cannot be cleaned with plain water use mild soap and water then rinse and wipe dry NEVER clean 2 Way Standing Seam Anchor with corrosive substances When not in use store equipment whe...

Page 9: ...am Anchor All inspection records must be made visible and available to all users at all times If equipment fails inspection or is involved in a fall REMOVE FROM SERVICE IMMEDIATELY INSPECTION DATE INS...

Page 10: ...10 General Work Products LLC 6000 Jefferson Hwy Harahan LA 70123 www PalmerSafetyUS com Fall Protection Training Netting PPE Notes...

Page 11: ...11 General Work Products LLC 6000 Jefferson Hwy Harahan LA 70123 www PalmerSafetyUS com Fall Protection Training Netting PPE Notes...

Page 12: ...Manual Revision 220225 General Work Products LLC 6000 Jefferson Hwy Harahan LA 70123 504 733 1808 www PalmerSafetyUS com Fall Protection Training Netting PPE...

Reviews: