PA168V MGCP FXS Gateway Telnet Setup Guide (V1.49)
13
set superpassword XXXX
Set super password of the
PA168V FXS gateway
. XXX must be
ASCII characters.
set debug X
Set open debugging message output grade for special tool. X
ranges from 0 through 5: 0: close debugging output; 1: output the
operation information to the window; 2: output all the bug
information and data in test window; 3: save
the bug information
into SDRAM; 4: disable checking the mark.
set password XXXX
Set password of the
PA168V FXS gateway
. XXX must be ASCII
characters.
set upgradetype X
Set auto-upgrade matching type
,
X ranges from 0 through 5
,
0------disable
;
1------all
;
2------ mac
;
3------ppp id; 4------ account;
5------ phone number
。
set upgradeaddr HTTP://XXX.XXX.XXX.XXX:PORT
FTP://XXX.XXX.XXX.XXX: PORT
TFTP://XXX.XXX.XXX.XXX: PORT
Set IP address or domain name of upgrade server supplying
upgraded program and configurations of PA168X IP phone.
set sntpip XXX.XXX.XXX.XXX