Install the PA-220R Firewall
Install the PA-220R Firewall in a 19-inch Equipment
Rack
The following procedure describes how to install the PA-220R firewall in a two-post or four-post
equipment rack using the 19-inch rack-mount kit.
You can purchase the 19-inch rack-mount kit separately from the
or an authorized reseller. Refer to SKU PAN-PA-220R-RACK4 when ordering.
STEP 1 |
Place the firewall upside-down on a table with the front of the firewall hanging off the edge
of the table by about three inches.
STEP 2 |
Place the shelf upside down on top of the firewall and align the four holes on the boom
of the shelf with the four screw holes on the boom of the firewall. The front bezel of the
firewall protrudes out of the front opening of the shelf.
STEP 3 |
Secure the shelf to the firewall using four 6-32 x 1/4” Phillips-head screws and torque each
screw to 9 in-lbs.
STEP 4 |
Hold the shelf (with the firewall aached) right-side up in the rack and secure the shelf to
the rack using two screws for each side of the shelf. Use the appropriate screws (#10-32 x