PA-5400 SERIES NEXT-GEN FIREWALL HARDWARE REFERENCE | Service the PA-5400 Series Firewall Hardware
73
©
2021 Palo Alto Networks, Inc.
STEP 4 |
With your replacement DPC in hand, rotate the card and align it with the front of the appliance
so that the Palo Alto Networks logo is readable at the top of the card.
STEP 5 |
Gently push the replacement DPC into slot 2, 3, 4 ,5 or 6 until the card reaches the end of the
slot. Push on both ejector handles until they lock the card into place.
PA-5400 Series Front Slot and Card States
You can view the slot and card status information on a PA-5400 Series firewall using the web interface or
the command line interface (CLI). From the web interface, select
Network
>
Interfaces
to view the status of
each slot. From the CLI operational mode, run the following command:
admin@PA-5450> show chassis status slot <slot-number>
For example, to show the status of slot 1, run the following command:
admin@PA-5450> show chassis status slot s1
For information on troubleshooting card slots and changing slot states, see