10
MISO 36 FIREBOWL CE Match-lit | Installation & Owner's Manual
STOP!
Review the safety information
on pages 1, 2 and 10 of this
manual.
Use only your hand to push
in or turn the gas control key.
Never use tools. If the key will
not push in or turn by hand,
don’t try to repair it, call a
qualified service technician.
Force or attempted repair
may result in a fire or
explosion.
Please ensure that you
are familiar with the safe
operation of the fire pit
controls before replacing the
instructional control knob
with the Paloform key.
The control key/knob is
meant to fit tight and be left
in place. Remove only for
winterization.
The gas valve has three positions: PILOT, ON and OFF.
To light your fire pit, you first light the pilot flame, then turn on the gas to main burner.
Before lighting, allow five minutes for any gas in the vicinity to dissipate. (LP gas,
which is heavier than air, may require forced ventilation).
1. Insert the control key (or control knob). Make sure the "half-moon"-shaped hole in
the end of the key and the valve stem are aligned.
2. The key should turn freely 90°. Turn the key to the PILOT position (clockwise until
it stops)
3. Push the control key in until it stops, and hold in this position.
4. Apply a flame to the lighting port with a barbecue lighter. The pilot flame will
ignite.
5. Continue to hold the key down for up to thirty seconds after lighting the pilot.
6. When the control key is released, the pilot flame should continue to burn (if the pilot goes out, repeat the above steps).
7. Rotate the gas control key from PILOT to ON position (full counterclockwise position) to supply full flow to main burner.
Failure to turn the control key to the full ON position will reduce the flow and could result in poor ignition of main burner.
8. To extinguish main burner, rotate the gas control key clockwise to the PILOT position.
9. To extinguish pilot, push the control key in slightly and turn to the OFF position (fully clockwise).
NOTE: We do not recommend leaving the fire pit unattended with the pilot lit. Please turn to the OFF position.
LIGHTING YOUR FIRE PIT
VALVE POSITIONS
PILOT
Push key in PILOT position to start the
flow of gas to the pilot. Light the pilot
while holding the key in
ON
Turn the key 90° counter-clockwise to
turn on the main burner. To turn the
main burner off, turn clockwise 90°
back to the PILOT position
To turn the pilot off, push slightly and
turn clockwise 90° to the OFF position.
OFF