6
HF-2500 Transformer
Installation Procedure
Here is the transformer and its mounting screws
Lift the transformer into amplifier chassis
Position the transformer over the mounting holes in
the chassis and insert the provided 1/4-20 Phillips
head screws through the transformer mounting tabs
and into the threaded inserts in the chassis plate and
tighten.
Plug the connector on the transformer into the mating
one on the wiring harness. It is keyed so that it can-
not be plugged in backwards. Make sure that the
connector halves are pressed together until the lock
tabs snap in place.
Plug the second connector on the transformer into the
mating one on the AC Mains PCB. It is keyed so that
it cannot be plugged in backwards. Make sure that
the connector is pressed in until the lock tabs snap in
place. Re-install top cover.
This completes HF-2500
transformer installation.