Here is the transformer and its mount-
ing screws
HF-2500 Magnum
Transformer Installation
Procedure
Position the transformer over the mounting holes
in the chassis and insert the provided 1/4-20
Phillips head screws through the transformer
mounting tabs and into the threaded inserts in the
chassis plate and tighten.
Lift the transformer into amplifier chassis
Plug the first connector on the transformer into
the mating one on the chassis wiring harness. It
is keyed so that it cannot be plugged in back-
wards. Make sure that the connector halves are
pressed together until the lock tabs snap in place.