9
OPERATING PROCEDURE
After reading this manual and completing the Installation/Preparation Instructions, position
the Commander VHF-144 front panel controls as follows:
•
ON/OFF — OFF
•
OPERATE/SSTANDBY — STANDBY
•
INPUT — CENTER ON SCALE (50-55 on Scale)
•
LOAD — MINIMUM (COUNTER-CLOCKWISE) (100 on scale is minimum capaci-
tance)
•
TUNE — LEAVE AT FACTORY SETTING (NOTE: the TUNE control is a multi-turn
piston capacitor and was factory preset for operation at 144.200 MHz.
Factory Setting Tune is 55.
After presetting these controls, switch the ON/OFF switch to the ON position. The meter
lamps will illuminate, the blower will be running and plate voltage will be approximately 2800
VDC.
The 3CPX800A7 used in this amplifier requires a warm up period before RF drive may be
applied, to prevent damage to the tube. A 2 minute warm up is provided by a microprocessor
circuit. During warm-up the green LED will flash at 1sec rate. At the end of the warm-up pe-
riod, the green POWER LED on the front panel illuminates on fully and the unit is ready for
operation.
Switch the OPERATE/STANDBY switch to the OPERATE position and key the exciter with
ZERO
RF drive applied. The Red Transmit light should illuminate, the tube will be biased
“on”, and plate idling current should be approximately 60 ma. as displayed on the Ip meter
scale.
Apply a very low RF drive (less that 5 watts) and adjust the INPUT control for a peak in the
plate current (Ip) on the meter. Next adjust the TUNE control for maximum output as indicated
on an external Wattmeter. DO NOT adjust the LOAD control at this time.
COMPLETE
THESE ADJUSTMENTS AS QUICKLY AS POSSIBLE TO AVOID STRESSING THE
TUBE.
Key the exciter in FM Mode (For Tune Procedure), and while increasing the RF drive, adjust
the LOAD control clockwise in order to keep the grid current below 40ma. and to obtain a peak
in output power on an external wattmeter (see chart: Typical Operating Conditions chart on the
next page).
Re-peak the TUNE control for maximum output at 600ma of plate current.
The Commander VHF-144 is ready for SSB or CW on the air operation. Normal SSB opera-
tion is indicated by plate current readings on voice peaks of approximately 1/3 to 1/2 of the CW
key down value.
For FM or other high duty cycle modes, limit drive to 10-15 watts maximum.
Summary of Contents for COMMANDER VHF-144
Page 12: ...12 Commander VHF 144 HV Power Supply...
Page 13: ...13 AC Mains and Step Start Board VHF 144 13 5VAC...
Page 14: ...14 Control and Metering Board VHF 144...
Page 15: ...15 RF Deck VHF 144...
Page 16: ...16 Commander VHF 144 T R Relay Board...
Page 17: ...17 Commander VHF 144 Voltage Doubler Power Supply Board...
Page 20: ...20 Meter Board Cathode Fuse...
Page 21: ...21 Step Start Board AC Main Fuse 20A x 2 AC Interlock Step Start Relays x 4...
Page 22: ...22 Power Supply 470uF Capacitor 450 vdc x 8 HV Sense RF Output...
Page 23: ...23...