8.3. 

Important notice regarding the network cable and amplifi er power

8.3.1. Permissible cable cross sections and lengths

8.3.2. RJ pin assignment

The following information is to ensure the safe operation of the loudspeaker with power amplifi ers. 

The maximum cable lengths and cable cross sections that may be used are indicated below. 

Pan Acoustics loudspeakers have a high effi  ciency. Due to the high sensitivity of the systems, a con-

siderable sound pressure can already be generated from little applied power. The RJ variants of the 

loudspeakers therefore do not have to be driven to the maximum in order to produce a sound level 

that is suffi  cient for the room, e.g. in conference applications.

Network cables are not suitable for transmitting high currents. It is therefore important to adjust the 

power of the DSP power amplifi er to the conditions, max. 20 watts (programme) / 60 watts (peak). 

Cables  have  an  electrical  resistance  and  can  heat  up  considerably  depending  on  the  cable  cross 

section. To prevent a cable fi re, the cross section of the cable must be suffi  ciently dimensioned.

WARNING

1

8

CAT5e or CAT6 cables are suitable for adapted power transmission if their cross sections correspond 

to 23 AWG or 24 AWG cables. Shielded cables are NOT required. 

For optimum power transmission, only use cables with copper cores.

NOTICE

8.3.3. RJ adapter

CAT cable cross section

Cable length (1 dB attenuation)

Cable length (1 dB attenuation)

22 AWG (0.326 mm²)

36 m @ 8 ohms 

72 m @ 4 ohms

23 AWG (0.258 mm²)

28 m @ 8 ohms

56 m @ 4 ohms

24 AWG (0.205 mm²)

22 m @ 8 ohms

44 m @ 4 ohms

The maximum cable length (24 AWG cable) between the power amplifi er and the loudspeaker with RJ 

socket should not exceed the length of 100 m @ 4 ohms and 60 m @ 8 ohms. 

The contacts of the loudspeaker’s RJ socket are wired in such a way that 4 wires (blue/brown) and 4 

wires (green/orange) are combined to one wire (+) and one wire (-). This assignment results in no 

polarity reversal when using a crossed network cable.

For connection to a DSP power amplifi er that is not equipped with a correspondingly assigned RJ 

socket, but e.g. with a 2-pin connection terminal, an adapter with Keystone socket is available. 

Summary of Contents for AMT P 04-AMT

Page 1: ...n Acoustics reserves the right to modify products without prior notice All products are designed developed and manufactured by Pan Acoustics in Germany Doc No 2022_01503 DOCUMENTATION SPEAKER B E A M...

Page 2: ...in a safe place so that it is available when needed If the product is resold the document must be handed over to the new owner in printed or electronic form Pan Acoustics reserves the right to change...

Page 3: ...0 8 2 Electrical connection 10 8 2 1 P 04 AMT RJ low impedance 10 8 3 Important notice regarding the network cable and amplifier power 12 8 3 1 Permissible cable cross sections and lengths 12 8 3 2 RJ...

Page 4: ...oduct properties available at the time of preparation and the safety regulations applicable at that time This operating manual describes the setup function and connection of the Pan AMT loudspeaker sy...

Page 5: ...arly marked and secured against accidental operation if the product shows signs of visible damage contains loose parts no longer works awlessly has been stored for a long time under unfavourable condi...

Page 6: ...red and labelled accordingly It must also be ensured that no intentional or accidental opera tion by third parties is possible The loudspeaker is suitable for indoor operation In outdoor areas the lou...

Page 7: ...ned according to the acting forces that may occur through lever e ects In case of doubt as to the type and composition of the building structure consult a structural engineer CONNECTION OF THE LOUDSPE...

Page 8: ...ket The bracket features three fixing points for mounting e g on a building surface To mount the U bracket on a surface it must first be removed from the loudspeaker After mounting the bracket on the...

Page 9: ...of 18 Manual Step 3 Secure plastic washer Mount the bracket on the desired building sur face When assembling position the plastic washers appropriately Assembly is done in reverse order NOTICE Step 2...

Page 10: ...24 AWG network cables Alternatively an adapter cable is available to operate the loudspeaker with DSP power amplifiers that do not have an RJ45 compatible port The U bracket can be swivelled from the...

Page 11: ...nect the network cable to the socket of the loudspeaker and snap it into place Step 2 Run the network cable with the RJ45 plug to the loudspeaker Check the locking mechanism of the connection cable fo...

Page 12: ...rably depending on the cable cross section To prevent a cable fire the cross section of the cable must be su ciently dimensioned WARNING 1 8 CAT5e or CAT6 cables are suitable for adapted power transmi...

Page 13: ...k the enclosure for damage Check the connection cable for damage 10 Service and repair 11 Maintenance measures The declaration of conformity for the relevant product from the Pan AMT series can be req...

Page 14: ...s IP54 and IP65 For further information on the warranty please refer to the Pan Acoustics warranty conditions https www pan acoustics de en service warranty 16 Mounts Recommended mounts for mounting p...

Page 15: ...r at least 600 W 4 ohms per channel Sensitivity 93 dB 1 W 1 m Maximum SPL 120 dB 1 m Impedance 4 ohms Horizontal radiation pattern 130 Vertical radiation pattern 20 Connections 1 x RJ45 Temperature ra...

Page 16: ...Pan Acoustics GmbH V 1 0 Page 16 of 18 Manual 18 Technical drawing loudspeaker 18 1 P 04 AMT RJ 506 mm 107 mm 116 mm...

Page 17: ...Pan Acoustics GmbH V 1 0 Page 17 of 18 Manual 18 2 P 04 AMT RJ mB 522 mm 137 mm 152 mm 107 mm...

Page 18: ...ACT Pan Acoustics GmbH Schweigerstr 13d D 38302 Wolfenb ttel Germany Tel 49 0 5331 900 95 70 Fax 49 0 5331 900 95 79 E mail contact pan acoustics de www pan acoustics de QUALITY MADE IN GERMANY SINCE...

Reviews: