5.

If the learning process was successful, the controlled equip-

ment should accept the IR command and turn off or go into
standby mode.

6.

Reprogram the IR command if the controlled equipment does

not respond. 

a

. Be sure that the batteries in the “teaching remote” are fresh

and do not need to be replaced.

b.

If “press & release” (Step 3 in Programming) doesn’t work,

try “press & hold” on the remote control button being taught to
the UPS.

RS232 Control with Open Protocol

The RS232 serial interface can be used in the following ways:

1. 

Initial system setup.  An installer can use a notebook comput-

er to set the variables within the Home Cinema Power Control

software.  Once the setup is completed, the notebook computer
can be disconnected.  All settings are stored in the UPS.

2.

Connection to a Home Theater Personal Computer (HTPC).

Functionality is very similar to a standard UPS with a PC.  
The UPS can provide continued power to the HTPC to maintain
recording capabilities if it is being used as a digital video
recorder.  It is also capable of saving open documents and 
shutting down the HTPC during extended power failures. 
This requires a permanent RS232 connection to the HTPC 
and having the Home Cinema Power Control software running 
in the background on the HTPC.

3.

Integration with home automation systems like AMX and

Crestron.  The serial communications command set and protocol
is open and is published later in this manual.  This information
can be used by the automation system programmer for both UPS
control by the automation system and reporting of power events
by the UPS to the automation system.

Advanced Operation 

(continued)

Home Cinema Power Control Software 

The M1500-UPS has one rear-panel serial port that provides the
ability to program special functions, safely shutdown a home the-
ater PC (HTPC) or integrate the UPS with home automation sys-
tems. 

Use of the Panamax software is optional. The communications
protocol is “open”; a programmer can write their own control
program or integrate the UPS’s programming/control functions
into home automation software if desired.  The UPS will pro-
vide surge suppression, automatic voltage regulation and bat-
tery backup without the software.  Automatic shutdown of an
HTPC requires the use of the software.

Software Installation

For Windows XP (Home and Professional) 
1.

Click on Start and then click on Control Panel.

2.

Double-click on Power Options then click on the UPS tab.

3.

Set the manufacturer to none.

4.

Exit to the desktop and shutdown your computer. 

5.

Turn the UPS off and unplug it.

6.

Connect the serial interface cable to the UPS and an open 

serial port on the back of the computer. (Note: You must use 
the serial cable that was supplied with the unit).

7.

Plug the UPS into an AC outlet, turn the UPS on and start your

computer. 

8.

Windows will recognize your UPS as “New Hardware”.

9.

Insert the software disk into the computer’s drive.  The instal-

lation program should start automatically.  If the installation 
program does not start automatically, open it manually with 
the Window’s “Run” command.

10.

Follow the on-screen instructions.

11.

Once the software has finished installing, remove the disk

and restart your computer.

For Windows 95/98/Me
1.

Turn off your UPS.

2.

Connect the Serial Cable to your UPS and the open serial port

on the rear panel of the computer. (Note: You must use the serial
cable that was supplied with the unit).

3.

Plug the UPS into an AC outlet, turn the UPS on and then start

your computer.

4.

Follow the instructions below for your PC’s operating system.

Summary of Contents for M1500-UPS

Page 1: ...ual POWER TEST MAX Home Cinema UPS Pure Sine Wave Intelligent Critical Load Control UNSAFE VOLTAGE LINE FAULT POWER ON AVR MODE BATTERY MODE BATTERY LEVEL LOAD LEVEL 1690 Corporate Circle Petaluma CA...

Page 2: ...tions pgs 7 8 9 10 Battery Features pgs 10 11 Diagnostics pg 11 Troubleshooting pg 12 Technical Specifications pg 12 RS232 Communications Protocol Command Set pgs 13 14 15 16 FCC Notice and Warranties...

Page 3: ...ife support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the ris...

Page 4: ...nd does not service equipment with large electri cal demands e g refrigerator copier etc Avoid using exten sion cords If used the extension cord must be rated for 15 Amps 5 Press the power switch to t...

Page 5: ...nd the 3rd above 75 The 4th arrow will flash when the load is between 85 and 100 Battery Level Indicator This is a visual indication of the battery charge If battery capac ity is under 25 no indicator...

Page 6: ...th outputs The IR LED s will flash once per second during the delay time and will stop flashing after the IR code is output 2 If the delay settings are the same for both IR1 and IR2 the IR2 code will...

Page 7: ...me Cinema Power Control Software The M1500 UPS has one rear panel serial port that provides the ability to program special functions safely shutdown a home the ater PC HTPC or integrate the UPS with h...

Page 8: ...and 12 Follow the on screen instructions 13 Once the software has finished installing remove the disk and restart your computer For Windows NT 4 0 1 Click on Start point to Settings then click Control...

Page 9: ...own the HTPC during extended power fail ures This requires a permanent RS232 connection to the HTPC and having the Home Cinema Power Control software running in the background on the HTPC When a power...

Page 10: ...ds to be used exclusively for the UPS software 12 Time between power failure and shutdown For use with an HTPC This is the user controllable delay between when the power fails and the software starts...

Page 11: ...tes and times of any scheduled startups and shut downs 7 Delete Clears the selected item from the schedule 3 Turn Off Select the day date and time that you want the computer system to shutdown This is...

Page 12: ...the red run button The unit will cycle to battery mode and emit an audible beep With the software self test the unit will switch back to AC power automatically Battery Replacement Read and follow the...

Page 13: ...eps Rapid Beeps Long Beep Long Beep None Off None Condition Normal AVR Max boost 13 of input voltage for output regulation while input voltage is from 8 to 15 under nominal AVR Max boost 26 of input v...

Page 14: ..._____________________________Yes Maintenance free____________________________________________________________Yes Lead acid___________________________________________________________________Yes User re...

Page 15: ...outlets on and off to force a hard reboot of equipment Devices such as satellite receivers often crash and must be reset The following are commands made by the controller to the UPS AC INPUT BATTERY M...

Page 16: ...pace 20 Hex XX is a number between 25 and 60 represented in ASCII If XX is a valid number between 25 and 60 Action Assigns the battery threshold variable with the value XX Response from UPS BTHRESH SP...

Page 17: ...is in AVR mode and bucking voltage by 11 Response from UPS AVRBUCK1 CR If the UPS is in BATTERY mode Response from UPS BATTERY CR Request Load Level Status Transmit the load level percentage Send to U...

Page 18: ...n AVR or BATTERY mode UPS is in AVR boosting 13 UPS is in AVR boosting 26 UPS is in AVR bucking 15 UPS is in BATTERY mode Battery charge falls below critical load threshold Input voltage exceeds high...

Page 19: ...e date of purchase that the unit shall be free of defects in design materi al or workmanship and Panamax will repair or replace any defective unit Upgrade Policy Valid only in the United states and Ca...

Page 20: ...1690 Corporate Circle Petaluma CA 94954 Tel 707 283 5900 Fax 707 283 5901 Email sales panamax com Web www panamax com 2005 Panamax INS0763 REV B 7 05...

Reviews: