background image

1                 2                 3                4                5             

    6                 7                8

UNSAFE VOLTAGE

    BREAKER

      WIRING FAULT

  TEMPERATURE

20 A

BRIGHTNESS

OUTLET STATUS

REBOOT 1                       REBOOT 2

M4320-PRO

B LT

Blue

 

ENABLED

   VOLTS

Power Management with Control System Interactive Functionality.

• 20 Amp Capacity M4320-PRO   
  
• 8 Individually Controllable Rear Panel Outlets

• Fully Programmable

• TCP/IP (BlueBOLT™) Installed

• RS-232 Card (Included, not installed) 

• Linear Filtration with 3 Isolated LiFT Filter Banks, 76db (5 kHz - 250 kHz), 46 db (250 kHz - 1 MHz) 

• One Isolated Filter Bank for High Current Devices, 60db (5 kHz - 450 kHz), 46 db (450 kHz - 1 MHz) 

• Front Panel Circuit Breaker

• Integrated Front Rack Ears

• 12 Volt Input Triggering

• Detachable 10 ft. Power Cord - 20A plug

• AVM & Protect-or-Disconnect Circuitry

M4320-PRO Instructions

INS00860 REV. D       5/10

    

Important:

 You will need the BlueBOLT-CV1’s unique MAC address and challenge key (provided on the 2 labels 

attached to the cover of the Quick Start Guide which is included in the M4320-PRO packaging). One label is 
permanently adhered to the Quick Start Guide and the other is removable for your convenience. 

B LT

Blue

ENABLED

Summary of Contents for M4320-PRO

Page 1: ...kHz 46 db 250 kHz 1 MHz One Isolated Filter Bank for High Current Devices 60db 5 kHz 450 kHz 46 db 450 kHz 1 MHz Front Panel Circuit Breaker Integrated Front Rack Ears 12 Volt Input Triggering Detacha...

Page 2: ...RIGHTNESS OUTLET STATUS REBOOT 1 REBOOT 2 M4320 PRO B LT Blue ENABLED VOLTS RS232 Table of Contents Feature Descriptions pg 1 Important Safety Instructions Front Panel Features Overview pg 2 Preset Pr...

Page 3: ...time This can cause speaker thumps which are not only annoy ing but can also damage the speakers and or trip product circuit breakers The M4320 PRO is designed to eliminate these transients by provid...

Page 4: ...te a full power up or shut down sequence The front panel outlet is always on unless the circuit breaker is set to OFF VOLTS AMPS BRIGHTNESS Ro tate knob for front panel brightness control and press to...

Page 5: ...off BREAKER or holding both REBOOT buttons A V EXTENDED DELAYS OUTLET SEQUENCING profile P3 by outlet s Start up 1 10 sec 2 10 sec 3 10 sec 4 10 sec 5 10 sec 6 10 sec 7 20 sec 8 Shut down 8 20 sec 7 2...

Page 6: ...75V clamping HD 1080i p ready 0 5 dB 0 Hz 2 2 GHz 5 LAN Cat 5e 10 100 1000BASE T compatible RJ 45 8P8C Ethernet protection pass through 6 Telco RJ 11 6P2C analog telephone DSL protection pass through...

Page 7: ...e or telephone DSL line from the M4320 PRO back to modem router s input Step 4 Plug in and switch on M4320 PRO SYSTEM SETUP 2 Network Equipment NOT Powered by M4320 PRO devices in separate rooms Step...

Page 8: ...________________________________________ __________________________________________ __________________________________________ __________________________________________ ______________________________...

Page 9: ...s list before proceeding The BlueBOLT CV1 should already be factory installed in this Panamax M4320 PRO component To switch from BlueBOLT functionality to RS 232 connectivity follow these steps 1 Unpl...

Page 10: ...4 ALL ON Turns on all outlets Turn on is immediate with no delay 3 4 1 Command ALL_ON CR 3 4 2 Action All outlet relays turn ON Terminates any running turn on or turn off sequence Overrides the DC tri...

Page 11: ...FOR 6 20 11 DELAY FOR 7 21 6 DELAY FOR 8 26 1 3 7 SET REBOOT DELAY Assign the delay between the last outlet turning off and the beginning of the turn on se quence in a reboot cycle 3 7 1 Command SET_R...

Page 12: ...e PROFILE n SELECTED CR 4 QUERIES 4 0 IDENTIFY Request that the unit identify itself 4 0 1 Query ID CR 4 0 2 Response PANAMAX CR MAX 4315 PRO CR FIRMWARE revision CR 4 1 FAULT STATUS Request the on of...

Page 13: ...R status CR 5 7 3 Condition When a wire fault is detected a message will be sent to indicate the status of the indicator 5 7 4 Message WIRE FAULT status CR 5 7 5 Condition When the temperature exceeds...

Page 14: ...number and a description of the problem Contacting Customer Service 2010 Panamax LLC 1690 Corporate Circle Petaluma CA 94954 www panamax com 707 283 5900 Fax 707 283 5901 INS00860 REV D 5 17 10 12 M43...

Reviews: