Telephone Circuit

Fuseless/Auto-resetting:........................................................................Yes
Clamping Level:..................................................................................260V
Capacitance:.........................................................................30pf (approx.)
Suppression Modes:...............................................Metallic & Longitudinal
Jacks:................................................................................................RJ-11 
Wires Protected:.............................................................2-Wire, Pins 4 & 5

Satellite TV Circuit

Bidirectional:.........................................................................................Yes
Shielded:...............................................................................................Yes
Clamping Level:....................................................................................25V
Attenuation:.................................................< 1db from 950MHz -2.05GHz

< 2.4db @ 2.2GHz

Connections:..........................................................Female “F”, Gold Plated

Cable TV Circuit

Bidirectional:.........................................................................................Yes
Shielded:...............................................................................................Yes
Clamping Level:...................................................................................1.4V
Attenuation:.................................................................< 1db up to 950MHz
Connections:..........................................................Female “F”, Gold Plated

AC Power

Line Voltage:..............................................................................120V, 60Hz
Total Current Capacity:.........................................................................15 A
UL1449 Suppression Rating:..............................................................330V 
Protection Modes:.................................................................L-N, L-G, N-G
Initial Clamping Level:.........................................................................200V
Energy Dissipation:..................................................................1815 Joules
Peak Impulse Current:............................................................73,000 Amps
Catastrophic Surge Circuit:....................................................................Yes
Thermal Fusing:.....................................................................................Yes
Over-voltage shutoff:.........................................................142 VAC ±5 VAC
Under-voltage shutoff:........................................................90 VAC ±3 VAC
EMI/RFI Noise Filtration

Banks 1 & 2:........................................................80 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets:..............................60 db, 100 KHz – 2 MHz

DC Trigger Input

Jacks:....................................................................3.5mm (1/8”) mini-plug  
Voltage and Polarity:.............................................3 - 24V DC, bidirectional
Current Requirement:........................................4.6 mA @3V, 58 mA @24V

LAN Circuit

Clamping Level:..............................................................................8V ± 2V
Jacks:................................................................................................RJ-45
Wires Protected:...................................................4-Wires, Pins 1, 2, 3 & 6

M5100-EX Specifications

Contacting Panamax

Contents

© 2005  Panamax. Panamax, MAX and the Panamax logo are registered US trademarks of Panamax.  Protect or Disconnect and SignalPerfect are trademarks of Panamax. 

SIDACtor is a registered US trademark of Teccor Electronics, Inc.

Specifications are subject to changes due to product upgrades and improvements.

Summary of Contents for M5100-EX

Page 1: ...nect your equipment from the power to protect equipment from damage Once the voltage returns to a safe level the MAX 5100 EX will automatically reconnect the power Protect or Disconnect AC Surge Prote...

Page 2: ...Outlet Bank 3 Two switched high current outlets controlled by the front panel Power Button or the DC Trigger input Bank 3 has a 5 second turn on delay and turns off immediately The High Current outlet...

Page 3: ...otal Current Capacity 15 A UL1449 Suppression Rating 330V Protection Modes L N L G N G Initial Clamping Level 200V Energy Dissipation 1815 Joules Peak Impulse Current 73 000 Amps Catastrophic Surge Ci...

Page 4: ...onnecting your equipment 4 DETERMINATION OF FAILURE Panamax will evaluate the protector for surge damage The Panamax protector must show signs of surge damage or must be performing outside 10 of desig...

Page 5: ...de la corriente para proteger su equipo de da o Una vez que la corriente regresa a una tensi n segura el MAX 5100 EX autom ticamente reconectar su equipo Proteger o Desconectar CA Protecci n de sobrec...

Page 6: ...de ruido de todos los otros tomacorrientes en el Banco 1 y 3 Tomacorriente Banco 3 Dos tomacorrientes de alta corriente conmuta dos controlados por el bot n Power o el Disparador CD en el panel de enf...

Page 7: ...Impulso 73 000 Amps Circuito de sobrecarga catastr fica Si Fusi n T rmica Si Interruptor de sobre tensi n 142 VAC 5 VAC Interruptor de sub tensi n 90 VAC 3 VAC Filtraci n de Ruido EMI RFI Bancos 1 2...

Page 8: ...ro de 30 d as Antes de desconec tar su sistema favor diagrame de su configu raci n porque un diagrama de su sistema se requerir como parte de sus documentos de reclamo 4 DETERMINACION DE FALLA El prot...

Page 9: ...long es De telles conditions constituent une menace tr s grave pour tout le mat riel lec tronique dans votre demeure Si le MAX 5100 EX constate que l alimentation n est pas s re il d branche automati...

Page 10: ...3 Deux sorties interrupteur haute intensit command es partir l interrupteur sur le pan neau avant ou par l entr e du d clencheur c c Le banc 3 a un d lai de mise en marche de cinq secondes tandis que...

Page 11: ...alisation Oui Seuil de calage 260V Capacit 30pf env Modes de suppression M tallique et longitudinal Prises RJ 11 Fils prot g s 2 fils broches 4 et 5 Circuit pour r ception t l par satellite Bidirectio...

Page 12: ...autorisation de retour Panamax vous postera une trousse de demande de r glement que vous devrez remplir et retourner dans les 30 jours Un sch ma de c blage de votre syst me sera exig Assurez vous de n...

Reviews: