background image

AC Power

Line Voltage:____________________________________________________120V, 60Hz
Total Current Capacity:__________________________________________________15 A
UL1449 Suppression Rating:____________________________________________330V 
Protection Modes:______________________________________________L-N, L-G, N-G
Initial Clamping Level:_________________________________________________200V
Energy Dissipation:______________________________________________1815 Joules
Peak Impulse Current:___________________________________________73,000 Amps
Catastrophic Surge Circuit:_______________________________________________Yes
Thermal Fusing:_______________________________________________________Yes
Over-voltage shutoff:__________________________________________142 VAC ±5 VAC
Under-voltage shutoff:________________________________________90 VAC ± 2 VAC
EMI/RFI Noise Filtration

Banks 1 & 2:________________________________________  80 db, 100 KHz – 2 MHz
Bank 3, High Current Outlets:____________________________60 db, 100 KHz – 2 MHz

Common Mode (all banks)______________________________60 db, 100 KHz - 2 MHz

DC Trigger Input

Jacks:_______________________________________________3.5mm (1/8”) mini-plug  
Voltage and Polarity:___________________________________3 - 24V DC, bidirectional
Current Requirement:_________________________________4.6 mA @3V, 58 mA @24V

LAN Circuit

Clamping Level:____________________________________________________8V ± 2V
Jacks:_____________________________________________________________RJ-45
Wires Protected:_______________________________________4-Wires, Pins 1, 2, 3 & 6

Telephone Circuit (pay-per-view)

Fuseless/Auto-resetting:_________________________________________________Yes
Clamping Level:______________________________________________________260V
Capacitance:__________________________________________________30pf (approx.)
Suppression Modes:____________________________________Metallic & Longitudinal
Jacks:_____________________________________________________________RJ-11 
Wires Protected:___________________________________________2-Wire, Pins 4 & 5
DSL Compatible:_______________________________________________________Yes

HD Satellite TV Circuit

Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________27V
Attenuation:______________________________________< 1db from 950MHz-2.05GHz

< 2.4db @ 2.2GHz

Connections:__________________________________________Female “F”, Gold Plated

HD Cable TV Circuit

Bidirectional:__________________________________________________________Yes
Shielded:_____________________________________________________________Yes
Clamping Level:_______________________________________________________1.4V
Attenuation:________________________________________< 1db from 5MHz - 950MHz
Connections:__________________________________________Female “F”, Gold Plated
Pay-Per-View Compatible________________________________________________Yes

MODEL  M5100-EX                                             UNIT CARTON

MASTER CARTON

Dimensions

Weight

Dimensions

Weight                UPC                  Qty        Dimensions               Weight

UPC

17" x 12.75" x 3.5"

14 lbs

23.75" x 19.25" x 9.5"       17.5 Lbs      0 50616 00785 6         1             Same as                 17.5 Lbs         5 00 50616 00785 1

4.1" H with feet

Individual Carton 

UPC’s, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING

OPTIONAL SILVER BEZEL

SILVER BEZEL

PRODUCT 

UNIT CARTON

MASTER CARTON

Model #                    Dimensions

Weight       Dimensions       Weight

UPC

Qty        Dimensions

Weight

UPC

BEZ5100-EXS      17" W x 0.625" D x 3.5" H     14.5 Oz        18" x 4" x 1"     18.0 Oz     0 50616 00791 7      N/A            N/A                 N/A                 N/A

1690 Corporate Circle, Petaluma, CA 94954   

800-472-5555 or 707-283-5900   

Fax - 707-283-5901  

• 

www.panamax.com

MAX

®

5100-EX REAR PANEL FEATURES

MAX

®

5100-EX SPECIFICATIONS

Specifications subject to change due to product upgrades and improvements.

Circuit Breaker

Automatically opens
when the current load
is greater than 15
Amps. 

Ground Lug

Provides a common
grounding point for
equipment with sep-
arate ground leads.

Main Power

Must be plugged
into a properly
wired & ground-
ed 3-wire outlet

Outlet Bank 1 

Four always on outlets.

Power will only be turned off

under a fault condition.  (See specifications for over-
voltage and under-voltage thresholds)  Power is cleaned
by a two-stage balanced Pi filter which also provides
noise isolation from Outlet Banks 2 and 3.

Outlet Bank 2

Four switched outlets

controlled by the front panel Power

Button or the DC Trigger input.  Bank 2 will turn on imme-
diately and turn off after 10 seconds.  EMI/RFI noise filtra-
tion is provided by a two-stage balanced Pi filter which
also provides noise isolation from Outlet Banks 1 and 3.

Outlet Bank 3

Two switched, high current outlets

controlled by the front panel Power Button or the DC

Trigger input.  Bank 3 has a 5 second turn on delay and turns off immediately.  The High
Current outlet provides power from a low impedance noise filtration circuit that does not
limit the current to your equipment.  Its output is noise isolated from all other outlet banks.  

Voltage Sense Trigger Input

3.5mm (1/8”) Mini-Plug jack.  Connect to
a remote trigger device that uses a DC
output to trigger a startup/shutdown
sequence.  This bypasses the front panel
power switch.  

LAN Jacks

Protection cir-
cuits for 10/100
baseT Ethernet
lines. 

Phone Jacks

Protection circuits for
standard telephone
or pay-per-view lines.
Phone circuit is auto-
resetting. 

Satellite TV Coax Jacks

Bidirectional protection circuit opti-
mized for satellite TV signal lines

Cable TV Coax Jacks

Bidirectional protection circuit opti-
mized for cable TV, off-air antennas
and cable modem signal lines. 

The Power Specialists Since 1975

®

© 2006 Panamax, Inc.  Panamax, MAX and the Panamax logo are registered US trademarks of Panamax.  Protect or Disconnect is a trademark of Panamax. SIDACtor is a registered US trademark of Teccor Electronics, Inc. 

Rack Mountable

(rack mount kit not included and sold separately - Rack Mount Kit / Double DIN, Part #

GRM2204)

Reviews: