M5100-PM BACK PANEL FEATURES
1. Circuit Breaker:
Automatically opens
when the current load
is greater than 15
Amps. Push to reset.
4. Outlet Bank 1
Four always-on outlets with linear filtration
technology (LiFT). Power will only be turned
of
f under a fault condition. (See specifications
for over-voltage and under-voltage thresholds)
Power is cleaned by a two-stage balanced Pi
filter which also provides noise isolation from
Outlet Banks 2 and 3.
5. Universal Coaxial
Connectors
3 pairs of bidirectional
protection circuits optimized for
satellite, cable, and antenna
TV signal lines.
3. Outlet Bank 2
Four isolated, switched outlets with linear filtration
technology (LiFT) controlled by the front panel
Power Button or the DC Trigger input. Bank 2 will
turn on immediately and turn off after 10 seconds.
LiFT
EMI/RFI noise filtration is provided by a two-
stage balanced Pi filter which also provides noise
isolation from Outlet Banks 1 and 3.
2. Outlet Bank 3
Two switched, high-current outlets controlled by
the front panel Power Button or the DC Trigger
input. Bank 3 has a 5 second turn on delay and
turns off immediately. The High Current outlet
provides power from a low impedance noise
filtration circuit that does not limit the current to
your equipment. Its output is noise isolated from all
other outlet banks.
6. Main Power
Must be plugged into a
properly wired & grounded
3-wire outlet
.
8. Bank 1 Indicator Light
Normally ON, is lit when
there is power present on the
Bank 1 receptacles.
10. LAN Jacks
Protection circuits for 10/100 baseT
Ethernet lines. Incoming LAN line MUST
be plugged into the LINE jack. Patch cord
to the equipment MUST be plugged into
the EQUIP jacks. 1 LAN jack goes to the
front panel output jack. 8 wire protection,
50V clamping.
9. Voltage Sense Trigger
Input
3.5mm (1/8”) mono mini-plug.
Connect to a remote trigger
device that uses a DC output
to trigger a startup/shutdown
sequence.
7. Ground Lug:
Provides a common
grounding point for
equipment with separate
ground leads
11. Phone Jacks
Protection circuits for standard telephone
or pay-per-view lines. Phone circuit is
autoresetting. Incoming phone cord MUST
be plugged into the LINE jack. Patch cords
to the equipment (satellite receiver, digital
video recorder, telephone, etc.) MUST be
plugged into the EQUIP jacks.
M5100-PM SPECIFICATIONS
UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
General________________________________________________________________
Dimensions......................................17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight........................................................................................................................13.5 lbs.
AC Power_______________________________________________________________
Line Voltage.........................................................................................................120V, 60Hz
Voltage Regulation.............................................................................................................No
Total Current Capacity......................................................................................15 A (1800 W)
Protection Modes.............................................................................................L-N, L-G, N-G
Initial Clamping Level.........................................................................200V Peak, 141V RMS
Energy Dissipation..............................................................................................2125 Joules
Peak Impulse Current........................................................................................60,000 Amps
Catastrophic Surge Circuit................................................................................................Yes
Thermal Fusing:...............................................................................................................Yes
Auto-resetting Over-voltage shutoff...........................................................142 VAC ± 8 VAC
Auto-resetting Under-voltage shutoff...........................................................86 VAC ± 6 VAC
EMI/RFI Noise Filtration___________________________________________________
Bank 1 ............................................................................... Up to -82 db (100 KHz – 2 MHz)
Bank 2 ............................................................................... Up to -80 db (100 KHz – 2 MHz)
Bank 3 ............................................................................... Up to -70 db (100 KHz – 2 MHz)
DC Trigger Input__________________________________________________________
Jacks....................................................................................... 3.5mm (1/8”) mono mini-plug
Voltage and Polarity.........................................................................3 - 24V DC, bidirectional
Current Requirement...................................................................4.6 mA @3V, 58 mA @24V
LAN Protection__________________________________________________________
Clamping Level.................................................................................................... 60V ± 5V
Compatibility......................................................................................................... 10/100bT
Connectors................................................................................................................RJ-45
Wires Protected:.....................................................................................................8-Wires
USB Circuit______________________________________________________________
Jacks...........................................................................................................................USB-A
Power Delivery.............................................................................................500 mA @5VDC
Telco Protection__________________________________________________________
Fuseless/Auto-resetting....................................................................................................Yes
Clamping Level..............................................................................................................260V
Capacitance.....................................................................................................30pf (approx.)
Suppression Modes...........................................................................Metallic & Longitudinal
Connectors...................................................................................................................RJ-11
Lines Protected.........................................................................................2-Wire, Pins 4 & 5
Universal Coax Protection_________________________________________________
HD 1080 i/p Ready...........................................................................................................Yes
Bidirectional......................................................................................................................Yes
Shielded...........................................................................................................................Yes
Clamping Level................................................................................................................75V
Frequency Range.........................................................................................0MHz - 2.2 GHz
Insertion Loss...........................................................................................................< 0.5 dB
Connectors......................................................................................Female “F”, Gold Plated
MODEL M5100-PM
MASTER CARTON
UNIT CARTON
Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC
17” x 12.75” x 3.5” 13.5 lbs 23.25” x 19” x 9.25” 18 Lbs 0 50616 00817 4 1 23.75” x 19.75” x 10” 19 Lbs 5 00 50616 00817 9
4.1” H with feet
1690 Corporate Circle, Petaluma, CA. 94954 • 800-472-5555 • 707-283-5900 • Fax 707-283-5901 • ww
w.panamax.com
© 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax
Design and specifications subject to change without notice due to product improvement.
L587 REV. D 12/09