background image

 M5300-PM BACK PANEL FEATURES

 M5300-PM SPECIFICATIONS

UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING

General________________________________________________________________

Dimensions .....................................17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)

Weight ..........................................................................................................................14 lbs.

AC Power_______________________________________________________________

Line Voltage ........................................................................................................120V, 60Hz

Voltage Regulation.............................................................................................................No

Total Current Capacity .....................................................................................15 A (1800 W)

Protection Modes ............................................................................................L-N, L-G, N-G

Initial Clamping Level ....................................................................... 200V Peak, 141V RMS

Energy Dissipation ..............................................................................................2350 Joules

Peak Impulse Current ...................................................................................... 75,000 Amps

Catastrophic Surge Circuit ...............................................................................................Yes

Thermal Fusing ................................................................................................................Yes

Auto-resetting Over-voltage shutoff ..........................................................142 VAC ± 8 VAC

Auto-resetting Under-voltage shutoff ..........................................................86 VAC ± 6 VAC

EMI/RFI Noise Filtration___________________________________________________

Bank 1 ............................................................................... Up to -86 db (100 KHz – 2 MHz)

Bank 2 ............................................................................... Up to -91 db (100 KHz – 2 MHz)

Bank 3 ............................................................................... Up to -81 db (100 KHz – 2 MHz)

Bank 4 ............................................................................. Up to -100 db (100 KHz – 2 MHz)

Bank 5, High Current Outlets ............................................ Up to -81 db (100 KHz – 2 MHz)

DC Trigger Input__________________________________________________________

Jacks....................................................................................... 3.5mm (1/8”) mono mini-plug

Voltage and Polarity........................................................................ 3 - 24V DC, bidirectional

Current Requirement.................................................................. 4.6 mA @3V, 58 mA @24V

DC Trigger Output________________________________________________________

Pass through........................................................................................................... no delay

Positive = Tip, Negative = Ring

LAN Protection__________________________________________________________

Clamping Level...................................................................................................... 60V ± 5V

Compatibility........................................................................................................... 10/100bT

Connectors.................................................................................................................. RJ-45

Wires Protected:....................................................................................................... 8-Wires

USB Circuit_____________________________________________________________

Jacks......................................................................................................................... USB-A

Power Delivery......................................................................................... 500 mA @ 5 VDC

Telco Protection__________________________________________________________

Fuseless/Auto-resetting..................................................................................................Yes

Clamping Level.............................................................................................................260V

Capacitance....................................................................................................30pf (approx.)

Suppression Modes..........................................................................Metallic & Longitudinal

Wires Protected.......................................................................................2-Wire, Pins 4 & 5

Connectors..................................................................................................................RJ-11

Universal Coax Protection________________________________________________

HD 1080 i/p Ready..........................................................................................................Yes

Shielded..........................................................................................................................Yes

Clamping Level...............................................................................................................75V

Frequency Range...................................................................................... 0 MHz - 2.2 GHz

Insertion Loss......................................................................................................... < 0.5 dB

Connectors.....................................................................................Female “F”, Gold Plated

Bidirectional....................................................................................................................Yes

Design and specifications subject to change without notice due to product improvement.

MODEL M5300-PM

MASTER CARTON

UNIT CARTON

         Dimensions                           Weight                     Dimensions                  Weight                        UPC                   Qty            Dimensions              Weight                        UPC

  

         

17” x 12.75” x 3.5”                      14 lbs                 23.25” x 19” x 9.25”          18 Lbs            0 50616 00816 7              1         23.75” x 19.75” x 10”     20 Lbs           5 00 50616 00816 2

       4.1” H with feet                                                                                                                                                                            

1690 Corporate Circle, Petaluma, CA. 94954  •  800-472-5555   •   707-283-5900  •  Fax 707-283-5901  •  ww

w.panamax.com

© 2009 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax

L590 REV. D 12/09

1. 15A Main Circuit 

Breaker: 

Automatically opens

when the current load

is greater than 15

Amps. Push to reset.

4. Outlet Banks 1 and 2

Each bank features two always-on outlets with 

linear filtration technology (LiFT). Power will 

only be turned off under a fault condition. (See 

specifications for over-voltage and under-voltage 

thresholds). LiFT

 EMI/RFI noise filtration is 

provided by a two-stage balanced Pi filter which 

also provides noise isolation from all other 

outlet banks.

5. Universal Coaxial  

Connectors

3 pairs of bidirectional 

protection circuits optimized for 

satellite, cable, and antenna 

TV signal lines.

3. Outlet Banks 3 and 4 

Each bank features two switched outlets with linear 

filtration technology (LiFT) controlled by the front 

panel Power Button or the DC Trigger input. Banks 

3 & 4 will turn on immediately and turn off after a 

10 second delay. LiFT

 EMI/RFI noise filtration is 

provided by a two-stage balanced Pi filter which 

also provides noise isolation from all other outlet 

banks.

2. Outlet Bank 5

Two switched, high-current outlets controlled by 

the front panel Power Button or the DC Trigger in-

put. Bank 5 has a 5 second turn on delay and turns 

off immediately upon shutdown. The High Current 

outlets provide power from a low impedance noise 

filtration circuit that does not limit the current to 

your equipment. Its output is noise-isolated from all 

other outlet banks.

6. Main Power Cord 10ft.

Must be plugged into a 

properly wired & grounded 

3-wire outlet

.

8. Bank 1 & 2 Indicator 

Light

Normally ON, is lit when 

there is power present 

on the Bank 1 and 2 

receptacles.

11. LAN Jacks

Protection circuits for 10/100 baseT Ethernet 

lines. For the LAN 2 protected jacks, the 

incoming LAN line MUST be plugged into the 

LINE jack and the patch cord to the equipment 

MUST be plugged into the EQUIP

 jack. For the 

LAN 1 protected jacks the incoming LAN line 

must be plugged into the LINE jack and the 

equipment must be plugged into the gaming 

jack on the front panel. 8 wire protection, 60V ± 

5V clamping.

10. Voltage Sense Trigger 

Input

3.5mm (1/8”) mono mini-plug. 

Connect to a remote trigger 

device that uses a DC output 

to trigger a startup/shutdown  

sequence.

7. Ground Lug: 

Provides a common 

grounding point for 

equipment with separate 

ground leads.

12. Phone Jacks

Protection circuits for standard 

telephone or pay-per-view lines. 

Phone circuit is autoresetting. 

Incoming phone cord MUST be 

plugged into the LINE jack. Patch 

cords to the equipment (satellite 

receiver, digital video recorder, 

telephone, etc.) MUST be plugged 

into the EQUIP

 jacks.

9. Voltage Sense Trigger 

Output

3.5mm (1/8”) Mini-Plug jack. 

Connecting a trigger wire to 

the V

oltage Sense Output jack 

will allow the input signal to 

pass through the M5300-PM to 

control the startup/shutdown of 

an additional device.

Voltage Protection Rating (UL1449 3rd Edition, 3,000A).............................................. 500V