Power Outlet Faceplate Installation Instructions

4 in.

3 3/4 in.

STEP 1:

Select a location close to the display device (Plasma TV, DLP, etc.).  In the case of a wall-mounted 

Plasma TV, this may be behind the display device and totally hidden from view once the Plasma TV 

is mounted.  Cut a 4-inch wide by 3 3/4-inch high hole in the wall for the In-Wall power cable (not 

included) and signal wires (not included).

STEP 2:

Run the AC wires through the lower-left entry of the included outlet box.  No more than 1 inch of wire 

sheath should extend into the outlet box. 3 inches of wire should be able to extend beyond the opening 

of the outlet box. Install the outlet box into the right side of the hole.

STEP 3:

Slide the included shrink-wrap tubing over the ground wire to prevent contact with the circuit board.  

Use the included wire nuts to connect the wires.

STEP 4:

Remove the blank module interface cover and run the signal cables through the opening.  

Keep the cover for use in STEP 6.

STEP 5:

Neatly fold the AC wires as you install the outlet faceplate into the wall with the AC side fitting into 

the outlet box.  Secure the unit to the outlet box with the included screws.

NOTE: 

Only the right side screws are used to mount the inlet faceplate into the included outlet box.  

The left side screws are for appearance only and are held on with the included plastic washers.  

All four screws are used when mounting the protector to a new-work electrical box and low voltage 

add-on bracket.

STEP 6:

The blank cover comes with a rectangular rubber plug that has a series of circular score-marks 

on the backside.  Using these score-marks as a guide, cut holes in the plug to match the number 

and size of signal-line cables.  Run the cables through the holes in the plug and reinstall the plug/cover 

combination into the opening of the base unit.  Be sure to leave enough signal-line cable to reach the 

display device.

Optional:

 Signal-line protection modules (sold separately) may be used instead of the blank cover/rubber 

plug combination.  Connect the signal cables to the appropriate Max In-Wall module and slide the module 

into the opening.  The module can be installed to three different depths, from flush to full recess.  

To remove the module, use the tool included with the module.

NOTE:

 

 The module shown is for illustration purposes, and is not included with the MIW-PowerKit-TL.  

A variety of modules are sold separately.  This product must be used with the blank module cover 

interface, or a signal line module installed.  Do not use this product in a “Fire-Break” wall unless 

a signal-line module is also installed.

PAGE 3

1

2

5

CIRCULAR

SCORE

MARKS

RUBBER 

PLUG

6

CAUTION:

 Not for use in “Fire-Break” walls unless used in conjunction with signal-line modules!

NOTE:

 For new construction (pre-wire): Use a Carlon new-work electrical box (Model B122A).  

A Carlon low voltage add-on bracket (Model SCIOOSC) may be used to indicate the size and location 

of the opening needed in the drywall.  The low-voltage bracket may be left in place when installing 

the outlet faceplate.

3

4

Summary of Contents for MIW-POWERKIT-TL

Page 1: ...rence 4 MAX POWER CORD MPC IEC 24 inch IEC Power Cord AC POWER CORD WITH TWISTLOCK CONNECTOR POWER INLET FACEPLATE POWER OUTLET FACEPLATE Plug into any receptacle for customized filtration needs Panamax MIW POWERKIT TL Installation Instructions MIW POWERKIT TL A four part kit designed specifically to provide the ultimate power solution to remote display devices within a home theater system Remote ...

Page 2: ...he included outlet box The left side screws are for appearance only and are held on with the included plastic washers All four screws are used when mounting the protector to a new work electrical box and low voltage add on bracket STEP 6 The blank cover comes with a rectangular rubber plug that has a series of circular score marks on the backside Using these score marks as a guide cut holes in the...

Page 3: ... new work electrical box and low voltage add on bracket STEP 6 The blank cover comes with a rectangular rubber plug that has a series of circular score marks on the backside Using these score marks as a guide cut holes in the plug to match the number and size of signal line cables Run the cables through the holes in the plug and reinstall the plug cover combination into the opening of the base uni...

Page 4: ...protector and the equipment to be protected must be indoors in a dry location and in the same building Panamax installation instructions and diagrams must be followed 2 NOTIFICATION You must obtain a return merchandise authorization RMA number from the Panamax Customer Relations Department at www panamax com support or toll free at 1 800 472 5555 before returning the protector to Panamax Once you ...

Reviews: