background image

800-472-5555  • www.panamax.com •  www.furmansound.com  

By

Panamax~Furman

INSTALLATION INSTRUCTIONS

MAX IN-WALL

™ 

SINGLE GANG SURGE PROTECTION

Features:

• Fits most standard single-gang plastic or metal box.

• Uses standard wiring device screw-hole.

• Mounting Yoke. 

  Designed to mount to any standard outlet box.  

• Decora Faceplate Interface. 

  This piece surrounds the receptacles and fits within 

  a standard cover plates Decora cutout.

• Bi-color Indicator LED.

  Green = Power On

  Red = Line Fault

• Mounting Screws. Two (2) 6-32 x .75” pan head

  screws are pre-installed, with retention features, 

  to mount the unit to an outlet box.

• Both Outlets with Protect-or Disconnect Circuitry.

   

MIW-SURGE-1G 

INS00885-A

Caution, Before You Begin: 

To avoid electrical shock or serious injury turn OFF all 

power leading to your installation of MIW-SURGE-1G such as circuit breaker or switch.

3 Wire nuts

included

Mounting:

1.

 Wire nuts (included) are used to connect the three 6 inch 

MIW-SURGE-1G wires. Connect the 

black (HOT)

 wire to the 

black

 

wire from the wall outlet, 

white (NEUTRAL)

 to 

white

 and the 

green (GROUND)

 wire to the (typically bare) 

ground wire.

2.

 The MIW-SURGE-1G is then installed in the outlet box just like any duplex 

receptacle or switch by driving the pre-attached screws into the outlet box.
    

3.

 Outlet box compatibility. This product is designed 

to fit into most standard metal or plastic outlet boxes.

Black = 

AC Hot

White = 

Neutral

Green = 

Ground

Reviews: