Table 4: Modbus address list – holding registers for flare meter validation (analog inputs)
Register tag name
Register
address
Number of
registers
Description
CH_CONFIG
2000
2
Channel configuration of the flare meter
UNITS_OF_MEASURE
2002
2
Units of measure configuration of the flare meter
CH4
2020
2
Methane concentration, fraction (0.0 to 1.0)
C2H4
2022
2
Ethylene concentration, fraction (0.0 to 1.0)
C2H6
2024
2
Ethane concentration, fraction (0.0 to 1.0)
C3H6
2026
2
Propylene concentration, fraction (0.0 to 1.0)
C3H8
2028
2
Propane concentration, fraction (0.0 to 1.0)
C4H10
2030
2
Butane concentration, fraction (0.0 to 1.0)
C4H10_ISO
2032
2
Iso butane concentration, fraction (0.0 to 1.0)
C4Hx
2034
2
C4’s (olefins) concentration, fraction (0.0 to 1.0)
C5Hx
2036
2
C5’s concentration, fraction (0.0 to 1.0)
C6Hx
2038
2
C6’s concentration, fraction (0.0 To 1.0)
H2S
2040
2
Hydrogen sulfide concentration, fraction (0.0 To 1.0)
VELOCITY_CH1
2100
2
Ch 1 velocity from flare meter
ERRORCODE_CH1
2102
2
Ch 1 error code from flare meter
SOUNDSPEED_CH1
2104
2
Ch 1 sound speed from flare meter
SIG_STRENGTH_CH1_UP
2106
2
Ch 1 upstream signal strength from flare meter
SIG_STRENGTH_CH1_DN
2108
2
Ch 1 downstream signal strength from flare meter
SIG_QUALITY_CH1_UP
2110
2
Ch 1 upstream signal quality from flare meter
SIG_QUALITY_CH1_DN
2112
2
Ch 1 downstream signal quality from flare meter
AMPLITUDE_CH1_UP
2114
2
Ch 1 upstream amplitude from flare meter
AMPLITUDE_CH1_DN
2116
2
Ch 1 downstream amplitude from flare meter
PEAKNUM_CH1_UP
2118
2
Ch 1 upstream peak number from flare meter
PEAKNUM_CH1_DN
2120
2
Ch 1 downstream peak number from flare meter
TTIME_CH1_SKAN_UP
2122
2
Ch 1 upstream transit time, skan from flare meter
TTIME_CH1_SKAN_DN
2124
2
Ch 1 downstream transit time, skan from flare meter
TTIME_CH1_MEAS_UP
2126
2
Ch 1 upstream transit time, measure from flare meter
TTIME_CH1_MEAS_DN
2128
2
Ch 1 downstream transit time, measure from flare meter
DELTA_T_CH1_SKAN
2130
2
Ch 1 upstream Delta T, skan from flare meter
DELTA_T_CH1_MEAS
2132
2
Ch 1 upstream Delta T, measure from flare meter
PATH_LENGTH_CH1
2134
2
Ch 1 path length from flare meter
AXIAL_LENGTH_CH1
2136
2
Ch 1 axial length from flare meter
VELOCITY_CH2
2200
2
Ch 2 velocity from flare meter
ERRORCODE_CH2
2202
2
Ch 2 error code from flare meter
31
Summary of Contents for flare.IQ Generation 2
Page 1: ...flare IQ Generation 2 Operation and maintenance manual...
Page 2: ...2...
Page 3: ...flare IQ Generation 2 Operation and maintenance manual 910 350 rev A June 2020 3...
Page 4: ...no content intended for this page 4...
Page 38: ...Figure 30 System wiring diagram 38...
Page 48: ...48...