03. Precautions for mounting and reflow soldering
03-1. Mounting
When mounting, a multifunctional mounter is recommended
If using a high-speed mounter, controle the suction force by using a multifunctional
head
In case of dry condition, please note the occurrence of static electricity.
The product may be adhered to the embossed carrier tape or the cover tape in dry
condition.
Recommended humidity is from 40%RH to 60%RH and please remove static
electricity by ionizer in manufacturing process.
03-2. Points to consider when selecting a pickup nozzle
for mounting
Select a pickup nozzle with a suction area that demonstrates a theoretical lifting force
at least
10 times
greater than the connector weight. .
Theoretical lifting force (g)
= Vacuum pressure (mmHG) /760
×
10.33
×
Nozzle area (
m
m
2
)
Example of machine vacuum pressure setting: 480–520 mmHg
1) Picking up the socket