background image

Max. 30m

Pipe 

length

Max. 20m

Level

difference

Long Piping

Random Auto Restart

All models are now safe to operate 
without a starter. With the exclusive 
Random Auto Restart feature, the air 
conditioners automatically restart after 
power failure. Its 32 different 
recovery-timing patterns ensure that air 
conditioners in the same building 
resume one after another instead of all 
at the same time. This feature helps 
prevent power surges after a blackout 
and walls are nearer too.

The basic piping can be extended, 
allowing the outdoor unit to be installed 
farther away from the 
indoor unit and 
providing greater 
installation flexibility.

*The graph refers to the CS-V18EKR.  *Extendable length varies 

by model.  *If the piping is extended past the basic pipe length, 

there's an extra charge for additional refrigerant.

Circulation Operation Mode

Personal Airflow Creation

Auto Changeover 

(

Inverter

)

Auto Changeover

Blue Fin Condenser

Soft Dry Operation Mode

Hot Start Control

Airflow Direction Control
(Up & Down)

Automatic Operation Mode 

(

Cooling

)

Top-Panel Maintenance Access

Reliable

This mode circulates the air in the room, 
to minimize differences in air 
temperature.

Starts with cooling to dehumidify. 
Then provides continuous breeze at low 
frequency to keep room dry without 

On the start of heating cycle and after 
defrost cycle, the indoor fan will start up 
once the indoor heat exchanger is warm.

Sensors measure the room and outside 
temperatures periodically. 
Based on these temperatures and the set 
temperature, the microcomputer 
determines the most suitable operating 
mode as time passes.

Vertical and horizontal air flow patterns 
can be combined as desired to gain the 
greatest possible comfort, with 
operation possible even from a distance 
by remote control.

When the Automatic Operation button is 
pressed, the optimum mode (cooling, 
soft dry) is selected based on data from 
the Intake Air Sensor. The desired 
temperature setting can also be set 
(Low, Normal or High).

Condensers can take a beating from 
exposure to salty air, rain and other 
corrosive factors. Panasonic has tripled 
the life of our condensers with an 
original anti-rust coating.

Maintenance of the outdoor unit used to 
be quite a tedious chore, especially 
when the unit was installed on a narrow 
balcony or attached to the outer wall of a 
high-rise building. Now, maintenance 
can be performed by simply removing 
the top panel, making these tasks much 
quicker and easier.

Should a malfunction occur, the unit 
diagnoses the problem and shows the 
corresponding alphanumeric code. This 
allows quicker servicing.

Every period

* at "AUTO" operation

Set

temperature

Room

temperature 

Outdoor 

temperature

Evaluates the three temperatures and 

selects the operating mode accordingly.

Auto Changeover System

Heat 

Dry  

Cool  

Checks three temperatures.

The flap swings up and down automatically, 
distributing air throughout the room. You 
can also adjust the airflow angle by 
remote control.

Self-Diagnostic Function

• Up & Down Airflow — 5 Pa Auto

• Left & Right Airflow — 5 Pa Auto

When you don't want 

airflow directed right 

at you.

When you want direct 

airflow.

When you want to 

warm yourself 

thoroughly from the 

feet up.

To focus the airflow to 

one side of the room.

To focus the airflow to 

the centre.

For uniform airflow 

throughout the room.

Not all features found on all models.

Blue Fins

Front View

Side View

Non-Blue Fins

Front View

Side View

This was tested by: 

1. Matsushita Air Conditioning R&D Centre Sdn. Bhd.

2. A third party authorized research institute in Malaysia.

Special Coating Layer 
(Fin Cross-section)

Cyclic Corrosion Test Results

Water Air

Salt 

content

Base material

Corrosion-

resistant layer

17

Summary of Contents for AC Robot 2006/2007

Page 1: ...Air Conditioners 2006 2007 ...

Page 2: ...Introducing Panasonic s original filter cleaning AC Robot Auto Cleaning Robot This powerful built in cleaning mechanism automatically cleans the filter to minimise filter clogging This maintains the air conditioner s original performance while eliminating the unpleasant job of cleaning the filter manually ...

Page 3: ... vacuums the dust from the filter and exhausts it outdoors each time you use it Always CLEAN Always POWERFUL Always EFFICIENT For a filter cleaning and dust exhaust mechanism in a room air conditioner As of November 2005 ...

Page 4: ...3 5 4 5 5 0 6 0 6 5 8 0 Indoor Deluxe p 14 CS E9FKR CU E9FKR CS E12FKR CU E12FKR CS E15FKR CU E15FKR Deluxe Wide p 14 DEO DEO CS E18FKR CU E18FKR CS E21FKR CU E21FKR CS E24FKR CU E24FKR CS E28FKR CU E28FKR Super Deluxe p 14 CS XE9EKE CU XE9EKE CS XE12EKE CU XE12EKE AC Robot Deluxe Deluxe Wide Indoor Single Split Wall Mounted AirQuality Features Capacity kW 2 0 2 5 3 5 5 0 6 5 p 15 p 15 ION ION CS ...

Page 5: ...05 ...

Page 6: ...mfortable Always CLEAN Without filter cleaning With auto filter cleaning Dust on filter after one year Test conditions Starting temperature and humidity 7 C 6 C Set temperature 23 C Fan speed airflow direction set to auto mode After air conditioning stabilizes Area of simulated house testing facility 16 5m2 Actual dust accumulation will vary depending on usage and environmental conditions 06 Clean...

Page 7: ...g status Vacuum duct The vacuum duct carries the trapped dust to the outside Air filter Original vacuum device Traps the dust from the intake air Dust exhaust and air ventilation fan Exhaust duct Trapped dust is automatically exhausted outside Actual dust accumulation will vary depending on usage and environmental conditions The exhaust duct discards the dust outdoors automatically The dust goes t...

Page 8: ...ving No filter maintenance will cause air volume to drop Less than 2 h 2 to 3 h 4 hours or more Time 1 h 30 min Operation time 4 h 2 round trip operations 2 round trip operations 2 round trip operations Cleaning starts at set time Cleaning starts No cleaning if less than 2 h Cleaning starts Air conditioner stops operation temporarily at the set time and cleaning starts 2 round trip operations or m...

Page 9: ...es Influenza Coxsackie virus etc Target substances Penetrates Filter Spike Virus Catechin How viruses are inactivated The virus is caught by the filter Catechin surrounds the virus The virus is inactivated Ventilation Control Powerful Mode Quiet Mode SUPER alleru buster filter Long life type 10 years The SUPER alleru buster filter combines three effects in one anti allergen anti virus and anti bac...

Page 10: ...collects allergens from the room s air A Supersonic Air Purifying System accelerates the air cleaning effect of the SUPER alleru buster filter It keeps room air cleaner to protect the family s health supersonic 10 ...

Page 11: ...nts of the highest Energy Efficiency Classification Super quiet Powerful heating top class energy efficiency Faster dust collection 23dB Indoor 1 46dB Outdoor 2 Anti allergen protection Inactivates more than 99 of all filter captured allergens Here inactivate means to suppress normal activity This inactivation of mite allergens has been verified by the University of Edinburgh in the UK Anti virus ...

Page 12: ... the frequency increases the output lowering the frequency reduces it In this way inverter air conditioners provide much finer temperature control than non inverter models Panasonic is harnessing its industry leading technologies to make life more comfortable With the slogan Technologies that deliver new levels of comfort the company is working to develop new high performance inverter air conditio...

Page 13: ...ys comfortable with an inverter air conditioner After quickly reaching the set temperature it finely adjusts output power to maintain a constant temperature So there are no uncomfortable temperature swings while electricity is used more efficiently Broad output power capability also assures continued comfort even if the number of people in a room changes And at maximum output an inverter air condi...

Page 14: ...9FKR CS E12FKR 2 60 0 80 3 00 3 60 0 80 5 00 8 870 2 730 10 200 12 300 2 730 17 100 4 33 4 26 3 50 0 80 4 00 4 90 0 80 6 70 11 900 2 730 13 600 16 700 2 730 22 800 3 63 3 89 CS E15FKR 4 40 0 90 5 00 5 50 0 90 7 10 15 000 3 070 17 100 18 800 3 070 24 200 3 21 3 50 CS E9FKR Quiet Indoor Quiet Outdoor CU E9FKR CU 15FKR CU E12FKR CU E18FKR E21FKR CU E24FKR E28FKR Model No Capacity kW Btu h EER COP W W...

Page 15: ...Comparison p 18 p 19 Specifications CU W18DKR W24EKR 2 30 2 45 7 840 8 350 3 24 3 63 5 30 5 75 18 100 19 600 2 93 3 19 2 75 3 05 9 380 10 400 3 14 3 53 3 60 3 90 12 300 13 300 3 27 3 58 CS W24EKR 7 03 7 80 24 000 26 600 2 97 3 17 CS W7DKR W9DKR V7DKR V9DKR 23dB 23dB In Quiet mode during cooling operation with low fan speed CS W12EKR Different design Without Ion Freshener CS W24EKR Different design...

Page 16: ...e Pressing the Powerful button cools or heats the room quickly It provides fast comfort with full power and a strong airflow This is perfect for use immediately after coming home or when unexpected guests arrive The start or stop operation time hour and minute can be set at one time Or both of the times for start and stop operation can be set LCD Wireless Remote Controller Inactivates more than 99...

Page 17: ...ble even from a distance by remote control When the Automatic Operation button is pressed the optimum mode cooling soft dry is selected based on data from the Intake Air Sensor The desired temperature setting can also be set Low Normal or High Condensers can take a beating from exposure to salty air rain and other corrosive factors Panasonic has tripled the life of our condensers with an original ...

Page 18: ...ntroller Blue Fin Condenser Random Auto Restart Top Panel Maintenance Access Self Diagnostic Function Long Piping Plug Type Ampere Capacity The plug must be installed Total room One room Healthy Air Quality Comfortable Convenient Reliable Split Type Feature Comparison CS XE9EKE CS XE12EKE Single Inverter Split Single Split Reverse cycle models Wall Mounted mode Refrigerants Type 15m 10A long life ...

Page 19: ... Dehumid Running Current Power Input EER COP Sound Pressure Level 1 dB A Sound Power Level dB A Net Weight Dimensions Height x Width x Depth L s 143 162 A 3 2 3 0 3 8 3 8 5 0 4 9 7 8 7 8 11 1 11 7 kW 0 72 0 685 0 875 0 865 1 1 1 09 1 81 1 80 2 37 2 46 3 19 3 58 3 14 3 53 3 27 3 58 2 93 3 19 2 97 3 17 Inside Hi Lo 34 26 36 26 36 26 39 26 41 29 42 29 43 38 42 38 47 41 46 41 Outside Hi Lo 47 49 49 50...

Page 20: ...ded to the included 2 metre hose if necessary Extension Hose 3m CZ HV3P Use to replace the included 2 metre hose for concealed piping use Use with the included 2 metre hose or the CZ HV3P is not permitted Maximum hose length is 5 m CS XE9EKE CS XE12EKE Replacement Hose 5m with Tip Cover CZ HV5P Dust Exhaust and Ventilation Hose Max Length 5m Refrigerant Pipe Max Length 15m CS XE9EKE CS XE12EKE Pan...