48 (E)
ENGLISH
Menu page P7
[TERMINAL INPUT SELECT]
P7
EXT TIMER IN
OFF
TIME ADJUST IN
9:00
[TERMINAL OUTPUT SELECT]
ALARM/SENSOR OUT
CONTINUE
ERROR WARN/REC OUT
WARNING
EXT TIMER OUT
START 0:00
END 0:00
[VIDEO OUT SEQUENCE]
SW INTERVAL
2s
BYPASS CAMERA
OFF
SW NOISE CANCEL
ON
LL CAMERA
OFF
[EXT SWITCHER]
MODE
VIDEO OUT
TERMINAL INPUT SELECT screen
Menu item
Description of function
EXT TIMER IN
For setting whether the signals from the external timer connected to
the rear panel terminal section are to be acknowledged in the
external timer recording mode.
ON : The signals from the external timer are acknowledged.
OFF : The signals from the external timer are not acknowledged.
Select OFF when using an external timer which has been
connected to the unit’s power cord.
TIME ADJUST IN
For setting the time to be set when signals have been input from the
component connected to TIME ADJ IN on the rear panel terminal
section.
00:00 to 23:59, RESET
Factory setting mode (9:00)
<Notes>
O
The seconds are fixed at “00.”
O
When signals are input after RESET has been set, the minutes of
the time are set to “00.”
The minute setting is returned to “00” while it is between 0 and 15
minutes when signals are input.
The hour is carried up and the minutes are set to “00” while the
setting is between 45 and 59 minutes when signals are input.
The underlining indicates the factory mode setting.
TERMINAL OUTPUT SELECT screen
Menu item
Description of function
ALARM/SENSOR
OUT
For setting how the control signals are to be output to the component
connected to ALARM OUT on the rear panel terminal section when
alarm recording or sensor recording is performed.
CONTINUE : The control signals continue to be output even after
recording.
ALARM REC : The control signals are output only during alarm
recording or sensor recording.
ERROR WARN/
REC OUT
For setting how the control signals are to be output to the component
connected to WARNING/REC OUT on the rear panel terminal
section when a problem has occurred in the unit.
WARNING : The control signals continue to be output.
REC
: The control signals are output only during recording.
EXT TIMER OUT
For setting the START time and END time at which the control
signals are to be output to the component connected to EXT TIMER
OUT on the rear panel terminal section.
0:00—23:59
<Note>
The control signals are not output when the same time has been set
for both the START and END times.
The underlining indicates the factory mode setting.
Setting menus