Chapter
Prepar
ation
DC OUT Connector and External REC Start/Stop Switch Connection
The DC OUT connector on the camera can output a 1.5 A
current.
Connecting an external switch to this connector enables
REC Start and Stop control.
An LED can be connected and used as a tally lamp, which
is convenient when the camera is mounted on a crane
during recording.
DCOUTconnector
1
2
3
4
Cableconnector
HR10A-P-P()
HiroseElectricCo.
(For details on connecting
the connector, refer to
page 164.)
Resist-
ance
REC
Start/Stop
(Connection example)
LED
1: GND
2: TALLY OUT
The AG-HPX300P has open collector output
TALLY ON:
Low impedance
TALLY OFF:
High impedance
3: REC Start/Stop switch
This pin is connected in parallel with the REC button
and the lens VTR button.
4: +12 V
NOTE:
Be sure to check polarity before connecting an external device
as incorrect connection could lead to damage.