Aicure ANUP5255V2
Setting
27
■
Intensity Setting
When executing “One- to four-step irradiation”, set the intensity and duration of UV irradiation for
each step.
“Intensity Selection” can be set by communication through the external device
connected to the RS-232-C terminal. See Page 57.
1
Call up the “Intensity Setting” screen.
Setting mode
Intensity setting
*(1)
0500
T0003
(2)
0700
T0003
(3)
0800
T0003
(4)
1000
T0003
Back
Back
Go
▲
(Back)
Moves to the option immediately above the
current option.
▼
(Next)
Moves to the option immediately below the
current option.
SET (Go)
Calls up the “Intensity Selection” screen.
Select “Intensity Setting” with the “
▲
” and “
▼
” buttons, and
press the “SET” button. Then the “Intensity Setting” screen is
called up. (The item is displayed inversely.)
2
With the “
▼
” button and the “SET” button, select a
desired irradiation pattern.
Setting mode
Intensity setting
*(1)
0500
T0003
(2)
0700
T0003
(3)
0800
T0003
(4)
1000
T0003
Back
Next
Set
▲
(Back)
Terminates “Intensity Selection” and returns to
the “Intensity Setting” screen.
▼
(Next)
Moves the irradiation pattern to 1 to 4.
SET (Set)
Goes into the setting of the selected irradiation
pattern.
Move the highlight bar with the “
▼
” button to the irradiation
pattern number you want to select. Press the “SET” button and
then the screen for setting the selected irradiation pattern will
be called up.
The irradiation pattern selected in “Intensity Setting” is indicated
by “*”.
Caution:
Reference: