Aicure ANUP5255V2
UV irradiation
45
■
Shutter timer/Illumination time/Change time
This function displays the settings and cumulative lamp ON time.
With the “
▲
” and “
▼
” buttons, select the “Shutter timer/Illumination time/Change time” screen.
Shutter timer
0005 Sec
Illumination time
1258 Hr
Change time
3000 Hr
Back Next
▲
(Back)
Moves to the option immediately above the
current option.
▼
(Next)
Moves to the option immediately below the
current option.
Shutter timer: Displays the irradiation time of Auto UV
irradiation when UV control is OFF.
* Set in the “setting mode”.
Illumination time: Displays the cumulative lamp ON time.
Change time: Displays the lamp-change time set value.
* Set in the “setting mode”.
■
Intensity setting detail
This function displays the “Intensity setting” value set in the “setting mode”.
With the “
▲
” and “
▼
” buttons, select the “Intensity setting detail” screen.
Intensity setting detail
*(1) 0700 T0003
(2) 1000 T0003
(3) 1500 T0003
(4) 2000 T0003
Back Next
▲
(Back)
Moves to the option immediately above the
current option.
▼
(Next)
Moves to the option immediately below the
current option.
The number indicated by “*” is selected.