Summary of Contents for AIG707WCL1G2

Page 1: ......

Page 2: ...hese specifications Do not dismantle or remodel the product It could cause excessive exothermic heat or smoke generation Do not touch the terminal while turning on electricity It could lead to an electric shock Use the external devices to function the emergency stop and interlock circuit Connect the wires or connectors securely The loose connection could cause excessive exothermic heat or smoke ge...

Page 3: ...uals can be downloaded on our website http industrial panasonic com ac e dl_center manual Unit name or purpose of use Manual name Manual code Programmable Display GT707 GT707 User s Manual Hardware WUME GT707H Screen Creation Tool GTWIN Ver 3 Terminal GTWIN Ver 3 Reference Manual ACGM0357V9EN General purpose serial communication GT series General purpose Serial Communication Manual English Edition...

Page 4: ...1 Names and Functions of Parts 2 2 2 1 1 GT707 2 2 2 1 2 Operation Mode Setting Switches 2 3 3 Installation and Wiring 3 1 3 1 Installation 3 2 3 1 1 Installation Environment 3 2 3 1 2 Restriction According to Mounting Directions 3 3 3 1 3 Installation Space 3 3 3 1 4 Mounting Screws 3 3 3 1 5 GT707 Installation Method 3 4 3 1 6 Installing in Vertical Orientation 3 5 3 2 Wiring the Power Supply 3 ...

Page 5: ...ment of Battery for Clock 3 15 4 Troubleshooting 4 1 4 1 What to Do If an Error Occurs 4 2 4 2 Error Codes and How to Handle Them 4 7 4 2 1 About Error Codes 4 7 4 2 2 GT707 Series Error Codes 4 7 4 2 3 When Connected to a FP Series PLC 4 9 4 2 4 When Performing General purpose Serial Communication 4 10 5 Specifications 5 1 5 1 GT707 Specifications 5 2 5 1 1 General Specifications 5 2 5 1 2 Perfor...

Page 6: ...t that would generate high switching surges 100 mm or more Static electricity Do not touch connector pins directly to prevent static electricity from causing damage Always rid yourself of any static electricity before handling this product If excessive static electricity is applied to the panel surface the LCD panel may be damaged Power Supply Twist the wires of the power supply The unit has suffi...

Page 7: ... adheres to your skin or clothes wash it away with soap On the LCD panel bright spots points always lit or black spots points always unlit may appear or the uneven brightness flickers or crosstalk appearance of unintended shades in the area no graphic or part is arranged may occur depending on the operating conditions Note that these phenomena are resulted from the basic characteristics of LCD pan...

Page 8: ...Before You Start vi ...

Page 9: ...1 System Configuration ...

Page 10: ...les Item name Specifications Model No PLC connecting cable For connecting our FP series TOOL port Cable length 3 m GT707 side D sub 9 pin female connector PLC side Mini DIN 5 pin round male connector PLC side connector L shaped AFC8503 PLC side connector Straight AFC8503S Note 1 Prepare a cable D sub 9 pin female loose wire connector separately for connecting the unit to FP7 control unit or FP7 co...

Page 11: ...nment and Applicable Cables Screen creation tool software Terminal GTWIN Ver 3 Item name Required OS Hard disk capacity Model number Terminal GTWINVer 3 English edition Windows 8 1 Windows 8 Windows 7 Windows Vista 800 MB or more AIGSGT7EN Note 1 As for 64 bit Windows only Windows 7 Windows 8 and Windows 8 1 are supported Use 32 bit Windows for Windows Vista Screen transfer cable Cable for connect...

Page 12: ...System Configuration 1 4 ...

Page 13: ...2 Names and Functions of Parts ...

Page 14: ... terminal Supplies 24 VDC Be sure to conduct functional ground when there is an influence of noise USB port Connector for the connection between the unit and a PC when using the screen creation tool software GTWIN A commercal USB cable is used SD memory card slot An SD memory card is inserted SD memory cards can be used for copying screen data and our PLC programs and used for the logging function...

Page 15: ...ear menu display and turning the power supply on Press GT Data to clear data in the user memory Press Holding Data to clear data in the hold memory Press PLC Backup Data to clear data backed up using the PLC backup restore function When memory clear is complete Cleared is displayed For resetting the condition to the normal use turn off the power supply change the operation mode setting switches to...

Page 16: ...Names and Functions of Parts 2 4 ...

Page 17: ...3 Installation and Wiring ...

Page 18: ...es or saline matter Benzine paint thinner alcohol or other organic solvents or strong alkaline solutions such as ammonia or caustic soda Direct vibration shock or places always exposed to drop of water This unit is warranted by IP65 for panel mounting however this applies to initial values Influence from power transmission lines high voltage equipment power cables power equipment radio transmitter...

Page 19: ... installing the GT unit if other parts are being installed to the panel or cables are being wired to it we recommend providing a clearance around the GT unit This prevents cables from being damaged and facilitates the installation work Also make sure that the slits in the main unit are never obstructed Model name Clearance Clearance on the surface to connect the screen transfer cable GT707 30 mm o...

Page 20: ...sert the fittings into the grooves of the GT unit and slide them to be fixed 3 Tighten the screws M3 Length 16 mm to secure the GT unit to the installation panel Enlarged view The cross slot screwdriver of 2 must be used The tightening torque of the screw M3 Length 16 mm should be 0 2 to 0 3 N m Tightening the screws too hard can cause deformation of the front panel so that the touch switches will...

Page 21: ... 3 1 6 Installing in Vertical Orientation The GT series can be installed upright The power supply connector is placed on the top side as illustrated below Select the vertical type when selecting a GT model in GTWIN 3 5 ...

Page 22: ...he power supply should be an insulated type and should be enclosed within a protective circuit The unit has sufficient noise immunity against the noise generated on the power line However it is recommended to take measures for reducing noise such as using an isolating transformer before supplying the power And it is recommended to take measures such as installing a ferrite core If a power supply d...

Page 23: ...nect them Do not solder the wires to connect them The solder may break due to vibration For tightening the terminal block use a flat blade screwdriver with a blade size of 0 5 x 3 mm After wiring make sure stress is not applied to the wire In the terminal block socket construction if the wire is fastened upon counter clockwise rotation of the screw the connection is faulty Disconnect the wire chec...

Page 24: ...s close as possible to the GT and keep the distance of the grounding wire short Sharing the ground with another device may have an adverse effect Therefore be sure that grounding is dedicated Conversely depending on your environment grounding may cause a problem Since the power line of the GT unit is connected to a functional earth via electronic parts the electronic parts may become damaged if th...

Page 25: ...2C Request to Send RS GT to External devices 8 RS 232C Clear to Send CS External devices to GT 9 N C Note 1 Do not connect anything to N C Note 2 Data cannot be sent unless the CS signal clear to send turns ON when selecting System Setting GT Configuration GT Communication Parameters from the GTWIN menu and setting CS RS Control to On When using the general purpose serial communication When using ...

Page 26: ...ith each control unit and the following FP X communication cassettes AFPX COM1 AFPX COM2 AFPX COM4 AFPX COM5 FPΣ Usable in combination with each control unit and the following FPΣ communication cassettes AFPG801 AFPG802 AFPG806 FP7 Usable in combination with each FP7 CPU unit or FP7 serial communication unit and the following FP7 communication cassettes AFP7CCS1 AFP7CCS2 AFP7CCS1M1 FP series COM p...

Page 27: ...t to Send 8 CS Clear to Send 9 N C FG Frame Ground GT707 series Wiring example Between FP series PLC TOOL port and GT707 2 Use the mini DIN 5 pin round connector for the connection on the FP series PLC TOOL port side The following figure shows the connection diagram with cables you construct The following connections are not necessary the connections of signal lines RS CS on GT707 side Nos 7 and 8...

Page 28: ...y 1 stop bit 38400 bps 8 btis odd parity 1 stop bit Communication conditions set in GTWIN Configuration settings Note The above order is for FP series PLC The pattern of the automatic communication settings varies depending on PLC models Conditions when the automatic settings mode is in effect If communication is attempted the specified number of times and there is no response from the PLC the GT ...

Page 29: ...ftware for the FP series FP7 series is booted on a PC connected to the GT series PLC programs can be edited or monitored through the GT series The through function is always enabled when the PLC type for GT is set to Panasonic PLC It can be used in combination with Panasonic PLC equipped with an interface The system should be set up so that the Timeout period in the FP series software A is larger ...

Page 30: ...ttery for clock Item name Appearance Specifications Model No Battery for GT707 clock For GT707 1 pc AFPABAT001 When using the battery for clock attach the battery before the power supply is turned on 3 5 2 How to Mount Battery for Clock PROCEDURE 1 Slide and remove the battery cover 2 Insert the connector to make the red line be the side 3 Set the battery in the circular frame 4 Attach the battery...

Page 31: ...ot held the BAT flag in the basic communication area map turns ON As necessary create a program for reporting the error to outside on the PLC side The BAT flag is allocated to the third word of the basic communication area bit device bit number 1 Default is the internal relay R21 The BAT flag is activated regardless of the setting of Battery Error Display Although the BAT flag goes on once when th...

Page 32: ...Installation and Wiring 3 16 ...

Page 33: ...4 Troubleshooting ...

Page 34: ...een content or specify the correct screen number When bringing up the keyboard screen during data input an unregistered keyboard screen number was specified Create and register a keyboard screen or specify the correct keyboard screen number GT configuration data and keyboard screen data exist in the GT but there is no base screen data Transfer base screen data from GTWIN Screen displays Memory is ...

Page 35: ...o change the setting change the setting of Backlight Control Auto Off The backlight brightness of GTWIN Configuration may be set low Select System Setting GT Configuration Basic Setup and change Backlight Brightness Setting Backlight goes off too quickly The setting of Backlight Control Auto Off is too short Change the set time of Backlight Control Auto Off Date time display is incorrect when usin...

Page 36: ...nstalled Refer to the installation guide and install the USB driver for GT Screen is blank power supply and substitution settings noted above do not apply An error has occurred in the GT system 1 After confirming the safety of the device etc turn off the power supply and then turn it on again The GT CPU will be reset 2 Set the operation mode setting switch 1 to ON turn on the power supply and clea...

Page 37: ...on the password change screen The password that has been already registered is tried to be registered Enter an unregistered new password Password setting incomplete is displayed on the password change screen There are items that are not entered Enter all items Your password cannot be deleted is displayed on the password management screen Your password was tried to be deleted Your password cannot b...

Page 38: ...ize SD memory card is damaged and data cannot be read because SD memory card was ejected during save Stop the logging of data Eject the SD memory card after turning on the setting for stopping the trigger occurence for all logging files in the record area control Activate the setting for stopping the trigger occurrence with switch parts etc Set not to save in the SD memory card Turn on the control...

Page 39: ...rror Screen data is not transferred correctly Re transfer data after deleting all data 0500 Tool setting error The device that cannot be used is specified for the data Check if the used device is correct e g the word device is set in the bit area 1000 SD memory card not inserted An SD memory card is not inserted into the slot properly Check the SD memory card slot 1001 SD memory card writing error...

Page 40: ...orcibly turned on or off 1040 The record area for logging was overwritten Check if an SD memory card is inserted 1041 Data cannot be written into the SD memory card Check whether the SD memory card is not write protected 1042 The memory of the SD memory card is full Delete some data in the SD memory card or prepare a new SD memory card 1044 The setting to stop writing to SD memory card has been se...

Page 41: ...porary error due to noise etc or error in the PLC Re supply power to the PLC and GT ER0041 Format error The PLC has been sent a command that doesn t match the protocol There may be a temporary error due to noise etc or error in the PLC Re supply power to the PLC and GT ER0042 NOT support error The GT has sent a non supported command to the PLC There may be a temporary error due to noise etc or err...

Page 42: ...error The address specified does not exist in the GT Check the address of the sent command 0004 Receive buffer overflow The sent command exceeds the receivable number of bytes Check the number of bytes of the sent command 0005 Requested overflow The sent readout command exceeds the number of bytes that can send back Check the number of the read words 0006 Data error The communication condition for...

Page 43: ...5 Specifications ...

Page 44: ...als and case 100 MΩ or more 500 V DC measured with megohmmeter at default setting Vibration resistance Conforms to IEC61131 2 5 to 8 4 Hz 3 5 mm single amplitude 8 4 to 150 Hz Acceleration 9 8 m s2 10 sweeps each in X Y and Z directions 1 octave min Shock resistance Conforms to IEC61131 2 147 m s2 3 times on X Y and Z directions EC Directive applicable EN61131 2 EMC Directive Noise immunity 1 000 ...

Page 45: ...ng 27 5 kbytes Logging data of Logging function 64 kbytes Hold GT Device 2048 255 words Hold PLC Device 24 words Battery Note 4 Application For driving the GT internal clock Life Approx 5 years at 25 C Note 1 On the LCD panel bright spots points always lit or black spots points always unlit may appear or the uneven brightness flickers or crosstalk appearance of unintended shades in the area no gra...

Page 46: ...ction Communication between our PLC and a computer is availalbe by connecting the computer to USB port and the PLC to COM port Copy function Screen data can be copied with a SD memory card Programs of Panasonic FP series PLCs can be uploaded downloaded via SD memory cards PLC backup restore function Note 5 Programs and registers of a Panasonic FP series PLC connected to the COM port can be backed ...

Page 47: ...col Master Slave Other companies PLC protocols Connector D sub 9 pin connector Male Interface for transferring screen data USB port Item Specifications Communication standard USB2 0 Connector shape Note 1 USB MiniB type 5pin Trasmission distance Max 5 m No of connected units with PC 1 Note 1 Take care of handling of the connector not to add an excessive static electricity on the metal part of the ...

Page 48: ...Specifications 5 2 Dimensions 5 2 1 GT707 Main Unit Dimensions Unit mm Panel cutout dimensions Unit mm 5 6 ...

Page 49: ...5 2 Dimensions 5 2 2 For Connecting PLC AFC8503 AFC8503S This is the cable used for connecting the GT707 to the tool port of Panasonic PLC FP0R FP X0 5 7 ...

Page 50: ...Specifications 5 8 ...

Page 51: ...Record of changes Manual No Date Record of Changes WUME GT707H 01 Aug 2015 1st Edition ...