– 6 –
Parts and Their Functions
Front Panel
1
Main unit power switch
Set this switch to the OFF position after quitting the
system. If the power is turned off while the hard
disk drive is operating, data may be lost or the drive
may be damaged.
Do NOT turn off the power while white characters
on a blue background appear on the monitor
display (for the personal computer) during startup.
2
Main unit power LED
3
HDD sub switch
Press this switch if PC unit’s power does not come
on even when the main unit power switch is set to
ON.
Do not press this switch without good reason since
the power of the PC unit will be turned off if it
pressed while the power is supplied.
4
HDD reset switch
Press this switch when the PC unit is not operating
properly. The start screen will now be restored,
and checks on the operation can be carried out.
Do NOT press this switch while white characters on
a blue background appear on the monitor display
(for the personal computer) during startup.
5
Phones jack
The sound can be monitored when stereo
headphones are connected to this jack.
6
Phones volume control
This is used to adjust the headphones volume and
the monitor output volume.
7
Mic jack
The microphone is connected here for voice-over
editing operations.
8
Mic volume control
This is used to adjust the level at which the
microphone sound is input.
9
Cassette slot
M cassettes or L cassettes are loaded through this
slot. Consumer-use cassettes cannot be used for
recording or playback.
:
Cassette tape EJECT button.
When this button is pressed, the tape is unloaded,
and the cassette is automatically ejected several
seconds later.
;
CD-ROM drive
<
Tray OPEN/CLOSE button
=
Floppy disk drive
>
Carrying handle
?
HDD access display lamp (system)
@
HDD access display lamp (AV data)
A
Screws for securing mechanism
Loosen these screws when cleaning the head
mechanism transport system of the VTR unit or
when conducting other kinds of servicing or
maintenance. It will then be possible to pull out the
VTR unit’s mechanism.
After the maintenance work has been completed or
when the unit is to be moved, the mechanism must
be put back inside the unit and the screws
tightened up securely.
9
6
5
8
=
4
?
@
7
3
;
2
:
A
>
1
<