27
Press the MENU-UP button or MENU-DOWN
button to move the cursor to the NO position,
and press the SET button.
The menu protection mode is now released.
3
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is now set to the menu protection mode.
When the LOCAL/MENU/REMOTE switch is set
to the MENU position, the unit is not set to the
menu setting mode, and “MENU PROTECTED”
appears on the video monitor screen.
<Note>
If, during the setting of the menu protection
mode, the LOCAL/MENU/REMOTE switch is set
to the MENU position while the COUNTER button
on the front panel is held down, the unit is set to
the menu setting mode, and the regular menu
settings can be performed.
Perform steps
2
to
7
of “Setting method using
the on-screen menus.”
5
Setup (initial settings)
Releasing the menu protection
mode
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the
COUNTER button on the front panel.
The unit is set to the menu setting mode, and the
menu screen appears on the video monitor.
1
2
MENU PROTECT OK?
2
NO
YES
Perform steps
2
and
3
of the menu protection
procedure described above.
The screen prompting the user to confirm
whether to initiate menu protection appears on
the video monitor.
Displaying the DIAG menu
Set the LOCAL/MENU/REMOTE switch to the
MENU position while holding down the EJECT
button.
The unit is set to the DIAG display mode, and the
hour meter and deck serial No. appear on the
video monitor.
1
Items with
“r”
can be reset when the unit is
serviced.
DIAG–MENU
HOURS METER
Ser
222222222
H00
OPERATION
00000H
H01
DRUM RUN
00000H
H02
TAPE RUN
00000H
H03
THREADING
00000T
H04
F LOADING
00000T
H11
DRUM RUN r
00000H
H12
TAPE RUN r
00000H
H13
THREADING r
00000T
H14
F LOADING r
00000T
The unit comes with a function for displaying the “hour
meter,” “software version” and “deck serial No.” on the
video monitor.
With the hour meter displayed, press the
SEARCH button.
The software version appears on the video
monitor.
2
The hour meter display is restored when the
SEARCH button is pressed again.
DIAG–MENU
SOFT VERSION
SYSIF
1.
22
-
22
-
2
.
22
AVDV
1.
22
-
22
-
2
.
22
SERVO
1.
22
-
22
-
2
.
22
END
Set the LOCAL/MENU/REMOTE switch to the
LOCAL or REMOTE position.
The unit is restored to its regular mode.