GUIDELINES FOR USAGE

 Operating voltage application time

If the rated voltage is applied to the coil for more than 10 
seconds or the maximum voltage is applied for more than 1 
second, coil performance may deteriorate.

 The shape of the mounting panel should be as 

recommended in the dimensions diagram.

Please contact us if you are considering using a panel of other 
than the recommended size and shape.

 The mounting panel should be made of SPCC. If 

mounted on soft or flexible materials, panel 

attachment may not be strong enough. Be sure to 

thoroughly check under actual operating conditions. 

Check this with actual application necessary.

Note that the actuator could come

off from the switch housing if 19.6N or more of force is applied 

to the side of the actuator.

Regarding fastening lead wires to terminals

1)  When connecting the .250 Quick- connect terminals, use a 

.250 receptacle and insert the terminals straight in. 
If you insert them at an angle, the terminals could catch on 
the opening and will require greater insertion force.

2)  The coil terminals have specific polarities. Make sure you 

connect them correctly.

3)  Use a receptacle that is compliant with JIS C 2809. In 

addition, there is some deviation regarding the insertion 

force depending on the model used from different 

manufacturers, so the insertion force should be checked 
under actual conditions.

4)  Use TE Connectivity Ltd.’s CT connector for the coil 

terminals.

 Because special receptacle terminals are used for the 

contact terminals and the common terminals, do not 

attempt to solder them. Doing so could melt plastic 

components and otherwise harm the performance of 

the switch

 The terminals should be connected in such a way 

that they are not under constant stress from the 

connecting wires.

 Take care not to drop the product as it may impair 

performance.

Resistance to chemicals

To clean the switch unit, use a neutral detergent diluted with 
water.
Do not use acidic or alkaline solvents as they may damage the 
switch.
Furthermore, be careful not to get any of the detergent solution 
inside of the switch while cleaning it.

 This product is not hermetically sealed, so its 

performance could deteriorate under certain ambient 

conditions. Avoid using and storing these switches in 

a location where they will be exposed to corrosive 

gases, silicon, or high dust levels, all of which can 

have an adverse effect on the contacts. In addition, 

because these switches contain permanent magnets, 

avoid using and storing these switches in a location 

where metallic dust, etc., is present.

 When these switches are used with weak currents of 

500 mA or less, a layer of material on the surface of 

the contacts may cause contact instability. Check and 

evaluate this possibility before using these switches 

under such conditions.

 When using an ON-OFF type switch with no (

|○

indication on the actuator, the “OFF” position should 

be indicated on the set in which the switch is 

installed.

 To assure reliability, check the switch under actual 

loading conditions. Avoid any situation that may 

adversely affect switching performance.

ー 6 ー

Summary of Contents for AJ8

Page 1: ...ION PART NO AJ 8 R 0 C F Number of pole and operation 1 1 pole single throw ON OFF 2 2 pole single throw ON OFF 5 1 pole double throw ON ON Coil voltage 1 5 V DC 3 12 V DC 4 24 V DC Terminal shape 0 250 Quick connect terminal C Upgraded type F Cadmium free product Actuator color Z Dark gray B Black Flange color Nil Dark gray B Black Function R Reset function Actuator indication 0 No indication 1 i...

Page 2: ...F AJ8R2001ZBCF 12 V DC AJ8R2003ZCF AJ8R2003ZBCF 24 V DC AJ8R2004ZCF AJ8R2004ZBCF With indication on actuator 1 With indication Actuator color Dark gray Poles Operation type Coil voltage Part No Flange color Dark gray Flange color Black 1 pole Single throw ON OFF 5 V DC AJ8R1011ZCF AJ8R1011ZBCF 12 V DC AJ8R1013ZCF AJ8R1013ZBCF 24 V DC AJ8R1014ZCF AJ8R1014ZBCF Double throw ON ON 5 V DC AJ8R5011ZCF A...

Page 3: ...Item Specifications Electrical life Manual operation Min 104 at 7 cpm at rated load Coil operation Min 5 104 at 7 cpm 5 A 125 V AC Mechanical life Min 5 104 at 20 cpm Contact resistance Initial Max 100 mΩ by voltage drop at 1 A 2 to 4 V DC Insulation resistance Initial Min 100 MΩ at 500 V DC measured by insulation resistive meter Dielectric strength Between contacts Initial 2 000 Vrms for 1 min de...

Page 4: ... terminals are 1 2 and 4 There are no other terminals Refer to the internal wiring diagram 3 The coil is a polarized coil coil terminal 5 is positive and coil terminal 6 is negative 2 4 1 3 5 6 32 0 16 4 φ1 75 4 4 10 6 8 6 13 5 16 0 2 0 15 0 6 35 29 8 0 3 Suitable connector CT connector 19 7 25 0 0 0 2 22 0 11 3 21 7 0 25 18 3 0 8 6 5 1 2 ON set 1 2 closed Reset 1 4 closed Set 1 2 closed 6 5 1 2 4...

Page 5: ...PLE Manual operation is a repetition of A and B This operation is independent of the electromagnetic reset function The reset mechanism operates only when an electromagnetic reset has occurred C Contact ON OFF Manual opening closing Iron core Manual operation Return spring Permanent magnet Coil Coil terminal Electromagnetic reset mechanism A B Manual operation Electromagnetic reset C Flips actuato...

Page 6: ... under actual conditions 4 Use TE Connectivity Ltd s CT connector for the coil terminals Because special receptacle terminals are used for the contact terminals and the common terminals do not attempt to solder them Doing so could melt plastic components and otherwise harm the performance of the switch The terminals should be connected in such a way that they are not under constant stress from the...

Page 7: ...ector Receptacle CONNECTION OF SIGNAL CONTACT TERMINALS Cable with connector Min order unit 1 bag set of 10 AJ8C0001 Reference Because CT terminals are used for the signal contact terminals TE Connectivity Ltd s CT connector can be used TE Connectivity Ltd s CT connector Pressure welding type 173977 2 for AWG26 28 2 179694 2 for AWG24 Crimping type 179228 2 Please refer to the latest product speci...

Page 8: ...lectrical resistance at the contact part Generally this resistance includes the conductor resistance of the spring and terminal portions Vibration resistance Vibration range where a closed contact does not open for longer than a specified time due to vibrations during use of the snapaction switches Shock resistance Max shock value where a closed contact does not open for longer than a specified ti...

Page 9: ...on the motor since a current flows that is several times that of the nominal current please select a switch taking into consideration the values in the table below To make the motor rotate in reverse use an ON OFF ON switch and take measures to prevent a multiplier current starting current reverse current from flowing Motor type Type Starting current Three phase induction motor Squirrel cage Appro...

Page 10: ...ittle if the switch is exposed to a low temperature low humidity environment for long periods of time Storage for extended periods of time including transportation periods at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and or it may interfere with the functions Check o...

Page 11: ...Electromechanical Control Business Division industral panasonic com ac e Specifications are subject to change without notice 1006 Oaza Kadoma Kadoma shi Osaka 571 8506 Japan Panasonic Corporation 2021 AECTB30E 202110 ...

Reviews: