background image

 

AJ8R

 

5

 

J8 SWITCHES WITH 

TRIP FUNCTION 

UPGRADED TYPE

 

POWER ROCKER SWITCH

FEATURES

 

1. Power switches with an electromag-
netic reset function which meet the 
need for energy savings in equipment 
and for safety.

 

Applications for these switches include 
promoting energy savings in equipment 
(by reducing power consumption when 
OA equipment is in standby mode, for 
example), preventing fires caused by 
overheating of a heater inside equipment, 
preventing electrical leaks, and automati-
cally turning off the power if the unit tips 
over or is shaken. These switches feature 
a built-in electromagnetic reset function 

that shuts off the main power supply in 
response to a signal that is received from 
an external sensor.

 

2. A dramatic upgrade in operation 
feelings 
These switches provide the same 
comfortable operation feelings our 
conventional J8 switches.
• Comparison of feel when switch is 
turned on

3. CT terminals adopted for coil termi-
nals

 

These switches can be used with AMP's 
CT connectors, which are widely used for 
wiring connections in OA equipment, 

making it possible to achieve greater effi-
ciency in wiring work.
Receptacle for AMP's CT connector 

receptacle socket

 

4. Prolonged electrical service life.

 

Coil operation provides an electrical life 
of at least 50,000 switching operations.

 

5. Assures excellent ability to with-
stand inrush current when used to 
turn a power supply on/off.

 

The switch uses our own proprietary 
mechanism that provides an excellent 
ability to withstand inrush current is 
employed.
Inrush current rating (IEC65) : 160A (nor-
mally 16A at 125V AC), 10,000 times

 

6. Approved under major international 
safety standards.

 

UL, cUL, TÜV and SEMKO approved.

Stroke

F

orce

Upgraded type

Conventional type

 

OPERATING PRINCIPLE

 

• Manual operation is a repetition of (A) and (B) .

This operation is independent of the electromagnetic reset function.

• The reset mechanism operates only when an electromagnetic reset has occurred. (C)

Contact

ON

OFF

Iron core

Manual operation

Return spring

Permanent
magnet

Coil

Coil terminal

Electromagnetic reset mechanism

(A)

(B)

(C)

Manual operation

Flips actuator

Manual opening/closing

Electromagnetic reset

Summary of Contents for AJ8R

Page 1: ...h AMP s CT connectors which are widely used for wiring connections in OA equipment making it possible to achieve greater effi ciency in wiring work Receptacle for AMP s CT connector receptacle socket 4 Prolonged electrical service life Coil operation provides an electrical life of at least 50 000 switching operations 5 Assures excellent ability to with stand inrush current when used to turn a powe...

Page 2: ...tage Flange color Dark gray Flange color Black Single pole ON OFF 5V DC AJ8R1001ZC AJ8R1001ZBC 12V DC AJ8R1003ZC AJ8R1003ZBC 24V DC AJ8R1004ZC AJ8R1004ZBC ON ON 5V DC AJ8R5001ZC AJ8R5001ZBC 12V DC AJ8R5003ZC AJ8R5003ZBC 24V DC AJ8R5004ZC AJ8R5004ZBC Double pole ON OFF 5V DC AJ8R2001ZC AJ8R2001ZBC 12V DC AJ8R2003ZC AJ8R2003ZBC 24V DC AJ8R2004ZC AJ8R2004ZBC 3 With O indications on actuators Actuator...

Page 3: ... rated load Min 5 104 at 7 cpm 5A 125V AC resistive load Mechanical life Min 5 104 at 20 cpm Initial contact resistance By voltage drop at 1A 2 to 4V DC Max 100mΩ Initial insulation resistance Min 100mΩ at 500V DC measured by insulation resistive meter Initial breakdown voltage Between contacts 2 000 Vrms Between coil and contact 4 000 Vrms Ambient temperature 0 C to 60 C 32 F to 140 F Not freezin...

Page 4: ...terminals are 1 2 3 and 4 In the case of the single pole single throw ON OFF type the contact terminals are 1 and 2 In the case of the single pole double throw ON ON type the contact terminals are 1 2 and 4 There are no other terminals Refer to the internal wiring diagram 3 The coil is a polarized coil coil terminal 5 is positive and coil terminal 6 is negative Wiring diagram Bottom view Single po...

Page 5: ...t stress from the connecting wires 8 Take care not to drop the product as it may impair performance 9 Resistance to chemicals To clean the switch unit use a neutral detergent diluted with water Do not use acidic or alkaline solvents as they may damage the switch Furthermore be careful not to get any of the detergent solution inside of the switch while cleaning it 10 This product is not hermeticall...