– 189 –
SYSTEM error messages
Message
AV NOT RESPONDING
SYSCON NOT
RESPONDING
S2 BOARD NOT
RESPONDING
S3 BOARD NOT
RESPONDING
S4 BOARD NOT
RESPONDING
S5 BOARD NOT
RESPONDING
L1 BOARD NOT
RESPONDING
L2 BOARD NOT
RESPONDING
CASSETTE LOAD FAIL
SUB LACING FAIL
MAIN LACING FAIL
HUB POSITION
Error description
The AV microcomputer is not working properly.
The reference signals from the S5 printed circuit
board may not be the prescribed ones or some
similar kind of problem is to blame.
A problem has occurred in communication
between the system control microcomputer and
front microcomputer.
The S2 printed circuit board has been removed.
The S3 printed circuit board has been removed.
The circuitry on the S4 PCB is not operating
properly.
The circuitry on the S5 PCB is not operating
properly.
The circuitry on the L1 PCB is not operating
properly.
The circuitry on the L2 PCB is not operating
properly.
A problem has occurred during the cassette
“down” operation.
A problem was detected during the sub-loading
operation, and the cassette was ejected. Check
the tape transport system.
A problem was detected during the main loading
operation, and the cassette was ejected. Check
the tape transport system.
The reel hub position does not match the
cassette size. The cassette was ejected as a
result.
On-screen display
SYSTEM ERROR
SYSTEM ERROR
SYSTEM ERROR
SYSTEM ERROR
SYSTEM ERROR
SYSTEM ERROR
SYSTEM ERROR
SYSTEM ERROR
MECHA ERROR
MECHA ERROR
MECHA ERROR
MECHA ERROR
Summary of Contents for AJHD3700B-PE
Page 193: ... 193 ...