67
Error messages
Error messages
E-55
UNLOAD
ERROR
If the tape has not been taken up during
unloading, this error number flashes on the
display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-53
WINDUP
ERROR
If there is an abnormally large discrepancy
between the amount of tape taken up by the
take-up reel and the amount of tape supplied by
the supply reel while the tape is traveling after
the total amount of the tape begins to be
detected, this error number flashes on the
display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-52
W-UP REEL
NOT ROTA
If the take-up reel fails to take up the tape while
the tape is traveling in the state where the total
amount of the tape has not yet been detected
after the cassette was inserted, this error
number flashes on the display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-38
SERVO FG
ERROR
If automatic adjustment of the reel and capstan
rotation in eject status was not performed
correctly when the power was turned on, this
error number flashes on the display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
Display
O
Description
O
VTR operation and corrective action
E-29
FRONT LOAD
MOTOR
The unit switches to eject mode and if the
cassette fails to move up within 6 seconds, this
error number flashes on the display.
O
If the cassette does not move down inside the
machine even when 6 seconds have elapsed
since the cassette was inserted, the VTR is
transferred to the eject mode.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-20
DEW
If condensation is detected, the error number
flashes and the unit transfers to eject mode. The
drum rotates after the cassette is ejected to
eliminate the condensation.
Once the unit is released from condensation
status, the error message display is cleared and
the VTR is able to be used.
O
If condensation is detected in the eject mode,
the drum starts rotating as soon as it is
detected.
O
If condensation is detected when the cassette
has been inserted, the drum rotation is
stopped, and after the tape is ejected, the
drum starts rotating.
VTR:
EJECT
O
Leave the power on and wait.
Display
O
Description
O
VTR operation and corrective action
E-31
LOADING
MOTOR
If the unloading operation is not completed
within 6 seconds, this error number flashes on
the display.
O
When the loading operation is not completed
within 6 seconds, the VTR is transferred to the
eject (unloading) mode.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-37
SERVO COMM
ERROR
If 10 seconds or more elapses and the servo
microcomputer has not followed orders issued
by the system control microcomputer, this error
number flashes on the display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-35
SERVO
CONTROL
ERROR
If there is no response from the servo
microcomputer for 1 second or more, this error
number flashes on the display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-57
S-FF/REW
TIMEOVER
If the start or end processing operation is not
completed, this error number flashes on the
display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-51
FRONT LOAD
ERROR
If the take-up reel rotates without engaging for a
specific period of time during the start or end
processing operation while loading is underway
(half position), this error number flashes on the
display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-60
DRUM ROTA
TOO FAST
If the cylinder motor speed is abnormally high,
this error number flashes on the display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-59
DRUM ROTA
TOO SLOW
If the cylinder motor speed is abnormally low,
this error number flashes on the display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
E-61
CAP ROTA
TOO SLOW
If the capstan motor speed is abnormally low,
the error number flashes on the display.
VTR:
STOP
O
Set the POWER switch to OFF and then to
ON again.
Summary of Contents for AJSD930P
Page 79: ......