- 1 (E) -
Operation procedure
1
Turn on the power of each
equipment.
2
Properly adjust the light for the
object.
3
Adjust the flange back of the lens,
the iris and the focus.
Flange back must be adjusted when
the camera is used for the first time
or after replacement of the lens.
4
Adjust the white balance.
This adjustment is needed when the
camera is used for the first time or
after leaving unused for a long time.
The adjustment is necessary when
the lighting condition or brightness is
changed.
After adjusting the white balance
once, re-adjustment is not needed
under the same condition.
5
Adjust the black balance.
This adjustment is needed when the
camera is used for the first time or
after leaving unused for a long time.
The adjustment is necessary when
the ambient temperature is greatly
changed or at the change of season.
After adjusting the black balance
once, re-adjustment is not needed
under the same condition.
6
Start shooting.
(After shooting, be sure to turn off the
power of each equipment connected.)
Summary of Contents for AK-HC1800G