25
Checking and setting the calendar
The calendar is checked and set on the [Date/Time] page located on the Maintenance menu.
p
Checking the current settings
1. Check the current year/month/day, day of the week and time displayed on [Present].
2. Select [Adjust], press the jog dial, and when [YES?] is selected and entered, the seconds are reset to “00.”
p
Adjusting the time
1. At [12H/24H], select whether the 12-hour or 24-hour system is going to be used.
2. At [Date], set the year, month, day and day of the week.
3. At [Time], set the hours, minutes and seconds.
4. At [Set Exe], when [YES?] is selected and entered, the adjusted year/month/day, day of the week and time are displayed
in [Present].
5. At [Reset], when [YES?] is selected and entered, the following is displayed:
00/01/01 MON
00:00:00
p
The calendar function will not operate properly when an irregular year/month/day, day of the week or time is set.
p
The manufacturer disclaims all responsibility for any trouble which may be caused by the calendar function.
Notes
Camera warning displays
Warning displays appear when errors have occurred in the camera’s auto functions.
Set [Status (AUTO)] to ON at [VF Display2] under [Operation].
p
When AWB is executed:
AWB LOW LIGHT
Auto white balance cannot be executed because the light quantity is insufficient.
Set the light quantity to the appropriate level.
AWB HIGH LIGHT
Auto white balance cannot be executed because the light quantity is excessive.
Set the light quantity to the appropriate level.
AWB R/Bch NG Out Range
The white balance convergence for the red or blue channel cannot be achieved.
Shoot a uniformly white object on the screen, and execute AWB.
p
When ABB is executed:
Not Finished
Auto black balance cannot be completed successfully.
The lens iris may not be open or the ND filter may not be set to CAP.
R/B Out Range
The black balance convergence for the red or blue channel cannot be achieved.
Check whether there are any abnormalities in the image.
p
When ASU is executed:
LENS CTL NG Out Range
The lens iris cannot be controlled.
Review the lens settings.
--- R/Bch NG
Trouble has occurred in the red or blue channel in the process which is being
executed.
Using a regular chart, check the correct position vis-à-vis the chart and angle
of view, check the colour temperature setting of the light source, and check
whether any other areas are not amenable to control.