ROP SETTING
C 0 1 : A K - U C 4 0 0 0
R O P S E T T I N G
LED
BRIGHT
7SEG-1
BRIGHT
LCD
BRIGHT
0
0.3
ON
DISABLE
NO?
NO?
1 / 1
CALL
PERIOD
BUZZER
CALL
CYCLE
PC_LINK
SETTING
STORE
SETTING
LOAD
7
3
10
7
7SEG-2
BRIGHT
___ indicates factory default settings.
Item
Setting value
Setting details
LCD BRIGHT
1 to 20
Sets the brightness of the LCD panel.
LED BRIGHT
1 to 5
Set the brightness of the panel buttons.
7SEG-1 BRIGHT
0 to 15
Sets the brightness of the panel's 7-segment display (group 1). This applies to the ND fil-
ter display, CC filter display, master gain display, and shutter display.
7SEG-2 BRIGHT
0 to 15
Sets the brightness of the panel's 7-segment display (group 2). This applies to the iris
display and camera selection number / master pedestal display.
BUZZER
ON
OFF
Enable or disable the buzzer (beep/call tone).
CALL PERIOD
0 to 5
[CALL PERIOD] and [CALL CYCLE] will be the time from which [CALL] was released for
[CAMERA CCU].
PERIOD: Flashing duration (sec).
CYCLE: Flashing cycle (For 1.0: 500 msec off → 500 msec lit (repeatedly)).
CALL CYCLE
0.3 to 1.0
PC_LINK
ENABLE
DISABLE
Sets whether to allow communication with ROP Setup Software.
ENABLE: Allows communication. This cannot be selected when an account is not
registered in ROP AUTH SETTING.
DISABLE: Does not allow communication.
NOTE
Set this to “DISABLE” when there will be no communication with ROP
Setup Software.
SETTING STORE
NO?
SET.1?
SET.2?
SET.3?
SET.4?
SET.5?
Stores up to five setting values (SET.1–5) related to the following operations of the unit.
Select the storage destination and then press the dial. If you do not press the dial, the
data will not be stored. You can use this according to purpose of operation.
[MAINTENANCE] > [ROP VOL/BUTTON]
[IRIS LEVER SETTING] > [LEVER MODE]
[IRIS LEVER SETTING] > [PRIORITY]
[IRIS LEVER SETTING] > [RELATIVE MODE]
SETTING LOAD
NO?
SET.1?
SET.2?
SET.3?
SET.4?
SET.5?
Select the data stored with U.SETUP STORE in SET.1–5, and reflect the settings in the
following menus by loading the data (pressing the [MENU] dial). You can recall setting
values according to purpose of operation.
[MAINTENANCE] > [ROP VOL/BUTTON]
[IRIS LEVER SETTING] > [LEVER MODE]
[IRIS LEVER SETTING] > [PRIORITY]
[IRIS LEVER SETTING] > [RELATIVE MODE]
- 118 -
ROP menu