23
█
Method for connection and use of accessory (AMK300-REM1)
For details, please refer to the
“
AMK300-REM1 Instruction Manual
”
.
1. AMK300-REM1 is connected with MK300 through RS485 communication and
allows performing the setting operation. Before use, please confirm communication
settings for the main unit of MK300.
Communication settings for the main unit of MK300 when using AMK300-REM1
(initial values of MK300 upon shipment)
P131: RS485 communication protocol selection "0"(MEWTOCOL)
P133: RS485 communication speed setting "1152" (115200 bps)
P134: RS485 stop length "1" (1 bit)
P135: RS485 parity "0" (no parity)
2. When AMK300-REM1 is connected, please set P003 for the main unit of MK300 as
"0" or "1".
3. When AMK300-REM1 is connected, the main unit does not allow performing the
following operations:
• Operating
RUN
key (run) from the main unit of MK300 (
STOP
key works)
• Changing parameters from the main unit of MK300 (only monitoring function
works)
If AMK300-REM1 is disconnected for more than 1 second, the main unit of MK300
will automatically enable operation from the main unit of MK300 by default.
CAUTION:
• When AMK300-REM1 is connected, parameters for the main unit of MK300 cannot
be set, but can only be monitored. After the main unit of MK300 and AMK300-REM1
are disconnected for 1 second, the main unit of MK300 restores the condition which
allows performing parameter setting.
• When P003 = 0 or 1, if AMK300-REM1 is connected, the
RUN
key on the main unit of
MK300 works, but
STOP
key does not work. After the main unit of MK300 and AMK300-
REM1 are disconnected for 1 second, the main unit of MK300 restores the function
of
RUN
key.
• When using AMK300-REM1 to upload, download and verify parameters with the
main unit of MK300, the external SW run signal becomes invalid even if it is received.
After the process of uploading, downloading and verifying is completed, the external
SW run signal becomes valid.