39
█
P0 Parameter List
No.
Function
name
Changes
during RUN
Setting range
Unit
Initial
value
P001
1st
Acceleration
Time
○
0.04 to 3600
0.01
[sec]*9
*4
P002
1st
Deceleration
Time
○
0.04 to 3600
0.01
[sec]*9
*4
P003
Run
Command
Selection
-
Setting
value
*1Reset
by
panel
Control
type
Details
-
0
0
Yes
Panel
Operation:
RUN
Stop:
STOP
Rotation direction:
dr Mode Setting
1
Yes
Panel
Forward:
+
RUN
Reverse:
+
STOP
Stop:
STOP
2
NO
External
control
Operation: SW1 ON
Stop: SW1 OFF
Forward: SW2 OFF
Reverse: SW2 ON
3
Yes
External
control
Operation: SW1 ON
Stop: SW1 OFF
Forward: SW2 OFF
Reverse: SW2 ON
4
NO
External
control
Forward run: SW1 ON
Stop: SW1 OFF
Reverse ru: SW2 ON
Stop: SW2 OFF
5
Yes
External
control
Forward run: SW1 ON
Stop: SW1 OFF
Reverse run: SW2 ON
Stop: SW2 OFF
6
NO
Communication Communication
command
7
Yes Communication Communication
command
P004
Frequency
Setting
Signal
-
0: Panel, input
1: External control, VR input
2: External control, 0 to 5V
3: External control, 0 to 10V
4: External control, 4 to 20mA
5: External control, 0 to 20mA
6: Communicatin, communication command
7: External control, PWM signal
8: External control, pulse train signal
-
0
Summary of Contents for AMK3000114
Page 59: ...58 ...