40
No.
Function
name
Changes
during RUN
Setting range
Unit
Initial
value
P005
Operation
Status
Monitor
-
0: Output frequency
1: Linear speed
2: Output current
3: Communication station
No.
4: Setting frequency
5: Communication station
No./Output frequency
6: Communication station
No./Linear speed
7: Communication station
No./Output current
8: Winding length
-
0
P006
Vector
Control
Selection
-
0: V/F control
1: Sensorless vector control
-
0
P007
Carrier
frequency
○
During V/F control: 0.8 to 15.0 (9 steps)
During sensorless vector control: 2.5 to 15.0 (6 steps)
[kHz]
2.5
P008
S-shaped
Acceleration
/Deceleration
Mode
-
0: Linear acceleration/deceleration
1: S-shaped acceleration/deceleration (Quadratic
curve)
2: S-shaped acceleration/deceleration (Cubic curve)
-
0
P009 V/FMode
-
50
:
50Hz mode
60
:
60Hz mode
FF
:
Free mode
3C
:
3-point type
3C1
:
3-point fixing 1
3C2
:
3-point fixing 2
3C3
:
3-point fixing 3
3C4
:
3-point fixing 4
3C5
:
3-point fixing 5
3C6
:
3-point fixing 6
-
50
P010 V/FCurve
-
0: Constant torque mode
1: Reduced torque mode
-
0
P011
Torque
Boost*7
○
0 to 40: Manual torque boost
Auto: Automatic torque boost
1[%]
*4
P012
Maximum
Output
Frequency
-
50.0 to 400.0
0.1[Hz] 50.0
P013
Base
Frequency
-
45.0 to 400.0
0.1[Hz] 50.0
P014
Change
Point
Frequency
1
○
0.2 to 400.0
0.1[Hz]
0.2
P015
Change
Point
Voltage 1
○
0.0 to 100.0
0.1[%]
0.0
P016
Change
Point
Frequency
2
○
0.2 to 400.0
0.1[Hz]
0.2
P017
Change
Point
Voltage 2
○
0.0 to 100.0
0.1[%]
0.0
P018
Maximum
Output
Voltage
-
0(Power supply voltage), 1 to 500
1[V]
0
P019 JOG
Frequency
○
0.2 to 400.0
0.1[Hz] 10.0
Summary of Contents for AMK3000114
Page 59: ...58 ...