4-3. Installing the Light Guide Fiber Unit
About the light guide fiber unit
The light guide fiber unit comes in a number of bundle diameters (3.5mm, 5mm, and 8mm), number of
branches (1 to 4), and other varieties. Select the type that meets your needs. To increase the UV
intensity, attach a lens unit (optional) to the irradiation outlet of the light guide fiber unit. To reduce the
temperature of the irradiation unit, attach a heat-ray blocking filter (optional) to the irradiation inlet of
the light guide fiber unit.
Installing the light guide fiber unit
1
Loosen the bolt on the fiber-unit mounting inlet on the
front of the main unit.
2
Press the light guide fiber unit into the fiber-unit mounting
inlet all the way, then tighten the bolt and lock it in place.