ANUP5204 Aicure
Starting and Stopping Operation
18
6. Starting and Stopping Operation
Start operation of the Aicure ANUP5204 in the following order: (1) turn on the power; (2) turn on the
lamp; and (3) begin irradiation (open the shutter). See 7. Irradiation Modes and 8. Irradiation for
details about irradiation modes and operation.
Here, we explain how to turn the power and the lamp on and off (common to every irradiation mode).
6-1. Starting Operation (turn on lamp)
1
Set the "POWER" switch in the up position.
2
Make sure that the display reads the cumulative lamp use
time, and you hear a beep.
3
In the "LAMP" section, press the "ON/OFF" button until
you hear a beep. The lamp turns on, and the LED above
the "ON/OFF" button lights.
4
Make sure that the "STABLE" (lamp stable display) and
"COOLING" (lamp cooling) LEDs in the "LAMP" section
are lit.
Wait about 30 seconds after the "STABLE" LED
lights before starting irradiation. Immediately after
the lamp is turned on, its light is unstable and low
intensity. Beginning irradiation in this state could
lead to defective curing, and should be avoided.
Warning