- 17 -
Press the Power Button on the Remote Control to select the Service Adjustment
For Adjustments:
Comb Filter Adjustment
Adj. Range
Default
Level
X0
COMB GAIN
0 ~ 255
152
X1
COMB SWITCH
0 ~ 63
12
X2
COMB LIMIT
0 ~ 63
24
X3
COMB CORE
0 ~ 127
41
X4
COMB RF DELAY
0 ~ 127
18
X5
COMB VIDEO DELAY
0 ~ 127
18
X6
COMB VMLM
0 ~ 127
90
X7
COMB VM SW
0 ~ 63
24
X8
COMB SHARP
0 ~ 255
30
X9
COMB VM LEVEL
0 ~ 255
255
Xa
COMB VMPKF
0 ~ 1
1
Xb
COMB ADJ SHARP
0 ~ 63
10
1.Press Channel Up/Down on the
Remote Control to select one of
the available Service Adjustments
(a in Fig. 14).
Note: Write Down the original
value set (b in
Fig. 14
) for
each address before
modifying anything. It is
easy to erroneously adjust
the wrong item.
2.Press Volume Up/Down on the
Remote Control to adjust the
level of the selected Service
Adjustment (b in Fig. 14).
CH
PW
IMPORTANT NOTE:
Always Exit the Service Mode
Following Adjustments.
To B Items.
CH
CH
Note: Some adjustments modes may not be
available in some models depending