SAFETY STANDARDS

Part No.

UL (Recognized)

VDE (Certified)

Remarks

File No. 

(Standard No.)

Contact rating

File No. 

(Standard No.)

Contact rating

(Basic insulation)

AC/DC

dual use

AQV251 (A)

E191218 

(UL1577)

0.5A 40V AC (peak) A connection

0.5A 40V DC A connection

0.7A 40V DC B connection

1.0A 40V DC C connection

-

AQV252 (A)

0.4A 60V AC (peak) A connection

0.4A 60V DC A connection

0.6A 60V DC B connection

0.8A 60V DC C connection

AQV255 (A)

0.35A 100V AC (peak) A connection

0.35A 100V DC A connection

0.45A 100V DC B connection

0.70A 100V DC C connection

AQV257(A)

0.25A 200V AC (peak) A connection

0.25A 200V DC A connection

0.35A 200V DC B connection

0.5A 200V DC C connection

AQV253 (A)

0.2A 250V AC (peak) A connection

0.2A 250V DC A connection

0.3A 250V DC B connection

0.4A 250V DC C connection

AQV254 (A)

0.15A 400V AC (peak) A connection

0.15A 400V DC A connection

0.18A 400V DC B connection

0.25A 400V DC C connection

AQV259 (A)

0.03A 1000V AC (peak) A connection

0.03A 1000V DC A connection

0.04A 1000V DC B connection

0.05A 1000V DC C connection

AQV258 (A)

0.02A 1500V AC (peak) A connection

0.02A 1500V DC A connection

0.025A 1500V DC B connection

0.04A 1500V DC C connection

Nr .40051981

(EN62368-1)

0.02A 1000V AC (peak) A connection

0.02A 1000V DC A connection

0.025A 1000V DC B connection

0.04A 1000V DC C connection

Part No.

UL (Recognized)

VDE (Certified)

Remarks

File No. 

(Standard No.)

Contact rating

File No. 

(Standard No.)

Contact rating

(Reinforced insulation)

AC/DC

dual use

AQV253H (A)

E191218 

(UL1577)

0.2A 250V AC (peak) A connection

0.2A 250V DC A connection

0.3A 250V DC B connection

0.4A 250V DC C connection

Nr. 40051981

(EN62368-1)

0.2A 250V AC (peak) A connection

0.2A 250V DC A connection

0.3A 250V DC B connection

0.4A 250V DC C connection

AQV254H (A)

0.15A 400V AC (peak) A connection

0.15A 400V DC A connection

0.18A 400V DC B connection

0.25A 400V DC C connection

0.15A 400V AC (peak) A connection

0.15A 400V DC A connection

0.18A 400V DC B connection

0.25A 400V DC C connection

AQV256H (A)

0.13A 600V AC (peak) A connection

0.13A 600V DC A connection

0.14A 600V DC B connection

0.16A 600V DC C connection

0.13A 520V AC (peak) A connection

0.13A 520V DC A connection

0.14A 520V DC B connection

0.16A 520V DC C connection

VDE(Basic insulation)

0.13A 600V AC (peak) A connection

0.13A 600V DC A connection

0.14A 600V DC B connection

0.16A 600V DC C connection

Note: For the latest information on compliance with safety standards, please refer to our website.

ー 7 ー

Summary of Contents for AQV251

Page 1: ...e Tape and reel packing style X 2 AC DC dual use 1 500 Vrms 40 V 500 mA AQV251 AQV251A AQV251AX 1 tube 50 pcs Outer carton 500 pcs 1 reel 1 000 pcs Outer carton 1 000 pcs 60 V 400 mA AQV252 AQV252A AQ...

Page 2: ...3 ms 2 ms 1 ms 4 ms 3 ms Turn off time Typical Toff 0 07 ms 0 09 ms 0 1 ms 0 06 ms 0 05 ms 0 04 ms 0 06 ms 0 05 ms 0 06 ms IF 5 mA IL Max Maximum 0 2 ms I O capacitance Typical Ciso 1 3 pF f 1 MHz VB...

Page 3: ...us load current A connection IL 0 4 A Continuous load current A connection IL 0 02 A AQV255 A Load voltage Peak AC VL 80 V AQV253H A Load voltage Peak AC VL 200 V Continuous load current A connection...

Page 4: ...urrent Max DC 4 1 Turn off time vs ambient temperature characteristics 40 0 0 1 0 2 0 3 0 4 20 0 20 40 60 80 85 AQV254 AQV254 AQV251 AQV252 AQV255 AQV251 AQV252 AQV255 AQV253 AQV257 AQV253 AQV257 AQV2...

Page 5: ...e characteristics 0 10 12 10 9 10 6 10 3 20 40 60 80 100 AQV259 Load voltage V Off state leakage current A Measured portion between terminals 4 and 6 Ambient temperature 25 C 9 2 Off state leakage cur...

Page 6: ...QV251 AQV252 Applied voltage V Output capacitance pF Measured portion between terminals 4 and 6 Frequency 1 MHz Ambient temperature 25 C 12 2 Output capacitance vs applied voltage characteristics 0 0...

Page 7: ...C A connection 0 04A 1000V DC B connection 0 05A 1000V DC C connection AQV258 A 0 02A 1500V AC peak A connection 0 02A 1500V DC A connection 0 025A 1500V DC B connection 0 04A 1500V DC C connection Nr...

Page 8: ...external noise surge static electricity and so on For noise effect to peripheral circuits when oscillation circuit operates please implement safety measures on the system before use by verifying opera...

Page 9: ...Emax is no higher than 6V GU and RF voltage sensitive type 5 Please make sure the input voltage for Emax is no higher than 30V Power voltage sensitive type Emin Emax 6 Please maintain the input voltag...

Page 10: ...ure rise at soldering lead is highly dependent on package size Therefore please set the lower temperature soldering condition than the conditions of item Soldering and confirm the temperature conditio...

Page 11: ...the package blister or crack This device is sensitive to moisture and it is packed in the sealed moisture proof package Please make sure the following condition after unsealing Please use the device...

Page 12: ...picked from 1 and 4 pin side Part No AQY VY AQY221 V1Y APV 111 VY APV 111 V1Y Shown above 2 When picked from 2 and 3 pin side Part No AQY VW APV 111 VW SOP 4 pin 1 When picked from 1 2 pin side Part...

Page 13: ...1 dia 300 2 dia dia Quality of material Paper DIP 6 pin Surface mount terminal 1 When picked from 1 2 3 pin side Part No AQV AX Shown above 2 When picked from 4 5 6 pin side Part No AQV AZ 21 0 8 13...

Page 14: ...art No APV1122AX Shown above 2 When picked from 4 6 pin side Part No APV1122AZ 21 0 8 13 0 5 17 5 2 2 0 5 2 0 5 80 1 80 1 dia dia dia 300 2 dia Quality of material Paper Note indicates characters of n...

Page 15: ...ed load voltage Load voltage Load current DC type AQZ102 60 V DC 4 0 A DC 5 12 24 V DC AQZ105 100 V DC 2 6 A DC 48 V DC AQZ107 200 V DC 1 3 A DC 100 V DC AQZ104 400 V DC 0 7 A DC 200 V DC AC DC type A...

Page 16: ...lectromechanical Control Business Division industral panasonic com ac e Specifications are subject to change without notice 1006 Oaza Kadoma Kadoma shi Osaka 571 8506 Japan Panasonic Corporation 2022...

Reviews: