Turquoise Stroke Switches (ASQ1)
Panasonic Corporation Electromechanical Control Business Division
industrial.panasonic.com/ac/e/
AECTB6E 202110
Panasonic Corporation 2021
TF
RF
OF
Stroke
Operation load
Contact force
Range of possible use
Operation load
N.O. side
N.C. side
N.C. side
N.O. side
RP (N.C.)
OP (N.C.)
OT (N.C.)
OT (N.O.)
TTP
OP (N.O.)
FP
RP (N.O.)
Standard ( mounting boss and hole center diameter or standoff )
0
0
(OFF)
Applicable range
100 mA
1 mA
0
30 V
5 V
DC
Operating characteristics*
Note 1
Characteristics
Pin plunger
Leaf lever
Simulated leaf lever
Operating Force (OF) Max. *
Note 2
1.5 N
1.7 N
1.5 N
Total travel Force (TF) Max. (reference value)
(2.0 N)
(3.1 N)
(2.8 N)
Free Position (FP) Max.
From mounting boss and hole center line
9.2 mm
11.5 mm
14.4 mm
From standoff
13.4 mm
15.7 mm
18.6 mm
Operating Position on N.C. side
(OP (N.C.) ) *
Note 3, 5
From mounting boss and hole center line
8.7±0.3 mm
9.8±0.5 mm
12.5±0.5 mm
From standoff
12.9±0.3 mm
14.0±0.5 mm
16.7±0.5 mm
Operating Position on N.O. side
(OP (N.O.) ) *
Note 4, 5
From mounting boss and hole center line
8.4±0.3 mm
9.3±0.5 mm
12.0±0.5 mm
From standoff
12.6±0.3 mm
13.5±0.5 mm
16.2±0.5 mm
Release Position on N.C. side
(RP (N.C.) ) *
Note 6
From mounting boss and hole center line
8.8±0.3 mm
10.1±0.5 mm
12.9±0.5 mm
From standoff
13.0±0.3 mm
14.3±0.5 mm
17.1±0.5 mm
Release Position on N.O. side
(RP (N.O.) ) *
Note 7
From mounting boss and hole center line
8.5±0.3 mm
9.6±0.5 mm
12.4±0.5 mm
From standoff
12.7±0.3 mm
13.8±0.5 mm
16.6±0.5 mm
Over travel on N.C. side (OT (N.C.) ) Min.
2.5 mm
3.1 mm
3.3 mm
Over travel on N.O. side (OT (N.O.) ) Min.
2.2 mm
2.6 mm
2.8 mm
Total Travel Position (TTP)
(reference value)
From mounting boss and hole center line
(5.9 mm)
(6.2 mm)
(8.7 mm)
From standoff
(10.1 mm)
(10.4 mm)
(12.9 mm)
Notes: 1. The above indicates the characteristics when operating the pushbutton from the vertical direction.
2. Indicates operation load for N.O. contact to achieve ON status.
3. Indicates position for N.C. contact to achieve OFF status.
4. Indicates position for N.O. contact to achieve ON status.
5. Although there is some overlap in the range of the operating position (OP) on the N.C. and N.O. sides due to the tolerance, in actuality there is always an intermediate OFF
range (the N.C. and N.O. sides will never ON at the same time.)
6. Indicates position for N.C. contact to achieve ON status.
7. Indicates position for N.O. contact to achieve OFF status.
OPERATION CONCEPT DIAGRAM
Contact form: SPDT
DATA
Applicable current range (Reference)
ー 4 ー