background image

AV3,AVM3/AVT3,AVL3

NOTES

2-(3) .110 Quick-connect terminal

5.5

7.1

11.0

16.1

8.8

NO

NC

C

±

0.1

±

0.15

0.6 max.

2.4

9.5

7.6

6.4

2.8

0.5

4.0

8.4

(P.T.)

6.7

7.7

3.3

-0.05

+0.1

2.4

2.5

±

0.3

±

0.1

±

0.1

(O.P.)

±

0.3

±

0.2

±

0.1

2.4

dia.

+0.1

-0.05

1.2

dia.

±

0.05

19.8

±

0.3

As for the dimensions of lever types, dimensions other than terminals are same as self-standing solder terminal.

mm General tolerance: 

±

0.25

1.Regarding fastening of switch body

In fastening the switch body, use flat 
filister head M2.3 screws, with tightening 
torque of not more than 0.29N·m.To 
prevent loosening of the screws, it is 
recommended that spring washers be 
used with the screws and adhesive be 
applied to lock the screws.
After mounting the switch and making 
wiring connections, the insulation 
distance between ground and each 
terminal should be confirmed as 
sufficient. 
The positioning of the switch should be 
such that the pushbutton or actuator for 
the switch should not directly apply force 
to the operating section in the free 
condition.For a pushbutton, the force 
from the pushbutton should be applied in 
a perpendicular direction.
In setting the movement after operation, 
the over-travel should be set not less 
than 70% as a standard.Setting the 
movement at less than 70% of O.T.may 
cause troubles such as mis-contact and 
welding due to small contact force of the 
switch.

2.Soldering operation

For manual soldering: 60W soldering 
iron, soldering completed within 3 
seconds; do not apply force to the 
terminals.
For automatic soldering tank: 250

°

immersion, completed within 6 seconds, 
350

°

C immersion, completed within 3 

seconds.
Terminal portions must not be moved in 
min.1 minute after soldering.Also no 
tensile strength of lead wires should be 
applied to terminals.

3.Regarding connector connections 
(.110 quick connect terminals)

 For making connections, a dedicated 
receptacle for .110 quick connect 
terminals should be used, and the 
terminals should be inserted parallel to 
the receptacle.Consideration should be 
given to mounting so that no tensile load 
is applied to the lead wires. 

4.In making the switch selection

 Consideration should be given to provide 
for no interference up to +20% variation 
of the standard characteristics values.

5.Environment 

 Locations where corrosive gases having 
a bad influence on contacts are present, 
and locations where there is an 
excessive amount of siliceous or other 
abrasive dust should be avoided.

6.Cautions regarding use

This subminiature switch has been 
designed as a dedicated switch for AC 
use, but it can be used for low capacity 
DC circuits.
Please select gold-clad contact types 
when loads are in the low-level area of 
1mA up to 100mA and 5V up to 30V.

For switching of inductive loads (relays, 
solenoids, buzzers, etc.), in order to 
prevent damage to contacts due to the 
occurrence of arcing, an arc absorbing 
circuit should be applied

7.Quality check under Actual Loading 
Condition

To assure reliability, check the switch 
under actual loading conditions.Avoid any 
situation that may adversely affect 
switching performance.

8.When using lever type switch, care 
should be taken not to apply undue 
force on the body from the opposite 
side or side ways to its operating 
direction.

N.C.
side

N.O.
side

Contact
force

Stroke

0

O.T. max.

Usable

area

P.T.

O.T. spedified
value

70% of O.T.

specified value

Ag

Au (-61)

Triple layer contact type

3 A

100 mA

1 mA

0

DC
AC

(Reference only)

5
5

15

30V
30

250V

All Rights Reserved © C

OPYRIGHT

 Panasonic Electric Works Co., Ltd.

Summary of Contents for AV(FS-FS-T)

Page 1: ...ounting Insulation guard available for safety mounting 2 lever pivot positions available for applications where low operating force is required TYPICAL APPLICATIONS Communication equipment Vending machines Security systems Data systems Medical equipment VCR PC board thickness 1 6 mm CONSTRUCTION Example AV3 AVM3 type Standard version Long life version Remark As for FS T switches the terminals are ...

Page 2: ... Short hinge lever 2 Hinge lever 3 Long hinge lever 4 Simulated roller lever 5 Roller lever Nil Standard 11 forward 5 1 47 N Operating force by pin plunger max Lever position International standard Nil AgNi alloy 61 Gold clad triple layer 3 UL CSA VDE SEMKO Ex AV M3 2 0 2 3 Type of switch Terminals Actuators Contacts 2 Solder terminal 4 PC terminal 8 110 Quick connect terminal AVT3 FS T switch Ver...

Page 3: ...13 AV3500613 0 49N AV3202613 AV3102613 AV3302613 AV3402613 AV3502613 0 98N AV3204613 AV3104613 AV3304613 AV3404613 AV3504613 Short hinge lever 0 098N AV3210613 AV3110613 AV3310613 AV3410613 AV3510613 0 20N AV3212613 AV3112613 AV3312613 AV3412613 AV3512613 0 39N AV3214613 AV3114613 AV3314613 AV3414613 AV3514613 Hinge lever 0 078N AV3220613 AV3120613 AV3320613 AV3420613 AV3520613 0 16N AV3222613 AV3...

Page 4: ...ever 0 20N AV36523 AV37523 AV38523 0 39N AV36543 AV37543 AV38543 Gold clad triple layer contact type Pin plunger 0 25N AV3600613 AV3700613 AV3800613 0 49N AV3602613 AV3702613 AV3802613 0 98N AV3604613 AV3704613 AV3804613 Short hinge lever 0 098N AV3610613 AV3710613 AV3810613 0 20N AV3612613 AV3712613 AV3812613 0 39N AV3614613 AV3714613 AV3814613 Hinge lever 0 078N AV3620613 AV3720613 AV3820613 0 1...

Page 5: ...VT32523 AVT34523 AVT38523 0 39N AVT32543 AVT34543 AVT38543 Gold clad triple layer contact type Pin plunger 0 25N AVT3200613 AVT3400613 AVT3800613 0 49N AVT3202613 AVT3402613 AVT3802613 0 98N AVT3204613 AVT3404613 AVT3804613 Short hinge lever 0 098N AVT3210613 AVT3410613 AVT3810613 0 20N AVT3212613 AVT3412613 AVT3812613 0 39N AVT3214613 AVT3414613 AVT3814613 Hinge lever 0 078N AVT3220613 AVT3420613...

Page 6: ...erminal Left angle terminal 110 Quick connect Without guard With guard With opposite side guard AgNi alloy contact type Pin plunger 1 47N AVM36053 AVM37053 AVM38053 Short hinge lever 0 59N AVM36153 AVM37153 AVM38153 Hinge lever 0 54N AVM36253 AVM37253 AVM38253 Long hinge lever 0 44N AVM36353 AVM37353 AVM38353 Simulated roller lever 0 54N AVM36453 AVM37453 AVM38453 Roller lever 0 59N AVM36553 AVM37...

Page 7: ...tal parts Between each terminal and ground 1 000 Vrms 1 500 Vrms 1 500 Vrms Vibration resistance Pin plunger type 10 to 55 Hz at single amplitude of 1 5mm Contact opening max 1 msec Shock resistance Pin plunger type Contact opening less than 1 msec 294 m s2 min O F 0 98 N 147 m s2 min O F 0 49 N 294 m s2 min O F 0 98 N 147 m s2 min O F 0 49 N 49 m s2 min O F 0 25 N 294 m s2 min Contact resistance ...

Page 8: ...N 0 029N 4th digit number of Part No O F max R F min P T max M D max O T max O P 0 2 8mm 0 8mm 1 2mm Distance from mounting holes 11 65 0 8mm Distance from stand off FS 15 05 0 9mm FS T 14 95 0 9mm 2 0 16N 0 015N 4 0 34N 0 029N 5 0 54N 0 034N 4th digit number of Part No O F max R F min P T max M D max O T max O P 0 2 5mm 0 5mm 0 8mm Distance from mounting holes 14 5 0 8mm Distance from stand off F...

Page 9: ...Pretravel Max mm 0 6 Movement differential Max mm 0 1 Overtravel Min mm 0 4 Operating position Distance from mounting hole mm 8 4 0 3 Distance from standoff mm 11 8 0 4 3 1 2 0 05 dia 8 7 0 1 15 4 0 1 Short hinge lever 12 85 5 0 NC NO C 0 4 2 5 max 6 6 4 0 12 2 O P P T 0 9 8 8 O P 0 8 Pretravel Max mm 2 5 Movement differential Max mm 0 5 Overtravel Min mm 0 8 Operating position Distance from mount...

Page 10: ...tance from standoff mm 15 05 0 9 Roller lever 3 2 5 0 dia NC NO C 5 15 0 4 2 5 max 17 9 O P P T 0 9 14 5 O P 0 8 Pretravel Max mm 2 5 Movement differential Max mm 0 5 Overtravel Min mm 0 8 Operating position Distance from mounting hole mm 14 5 0 8 Distance from standoff mm 17 9 0 9 1 5 Internationally common pitch PC terminal P T 0 6max 4 0 2 4 1 3 4 0 3 2 7 4 6 C0 3 7 62 0 1 19 8 0 3 7 62 0 1 O P...

Page 11: ... board terminal Pin plunger 6 4 3 2 7 0 1 2 0 5 16 1 8 8 19 8 NO NC C 0 3 0 2 0 1 0 6 max 2 4 9 5 7 6 4 0 8 4 P T 6 7 7 7 3 3 0 05 0 1 2 4 2 5 0 3 0 1 0 1 O P 0 3 2 4 dia 0 1 0 05 PC board pattern 10 9 Button position 8 8 0 1 16 1 0 1 3 1 35 to 1 50 dia Pretravel Max mm 0 6 Movement differential Max mm 0 1 Overtravel Min mm 0 4 Operating position Distance from mounting hole mm 8 4 0 3 Distance fro...

Page 12: ...8 12 85 Pretravel Max mm 2 8 Movement differential Max mm 0 8 Overtravel Min mm 1 2 Operating position Distance from mounting hole mm 11 65 0 8 Distance from standoff mm 14 95 0 9 Roller lever NO NC C 3 2 5 0 dia 5 15 0 4 2 5 max P T 14 5 O P 0 8 Pretravel Max mm 2 5 Movement differential Max mm 0 5 Overtravel Min mm 0 8 Operating position Distance from mounting hole mm 14 5 0 8 Distance from stan...

Page 13: ...min 1 minute after soldering Also no tensile strength of lead wires should be applied to terminals 3 Regarding connector connections 110 quick connect terminals For making connections a dedicated receptacle for 110 quick connect terminals should be used and the terminals should be inserted parallel to the receptacle Consideration should be given to mounting so that no tensile load is applied to th...

Reviews: