background image

8

Contents

Contents

Read this first! (For AV-HS60U1P/AV-HS60U2P) 

  

 

2

Read this first! (For AV-HS60U1E/AV-HS60U2E) 

  

 

5

Overview 

  

 9

Overview 

  

 9

Ratings display 

  

 9

Installation 

  

 9

Accessories 

  

 9

Part Names and Functions 

  

 10

Front panel 

  

 10

Rear panel 

  

 10

Notification when the power is turned on for the first time 

  

 12

Specifications 

  

 13

How to read this document

 

r

Abbreviations

The following abbreviations are used in this document.

 

f

The model numbers of the Main Frames AV-HS60U1P/AV-HS60U2P, AV-HS60U1E/AV-HS60U2E are described as “AV-HS60U1”/“AV-HS60U2”.

 

f

The model numbers of the Control Panels AV-HS60C1P/AV-HS60C2P, AV-HS60C1E/AV-HS60C2E are described as “AV-HS60C1”/“AV-HS60C2”.

 

f

The model numbers of the Control Panels AV-HS60C4P and AV-HS60C4E are described as “AV-HS60C4”.

 

f

The model number of the Menu Panel AV-HS60C3G is described as “AV-HS60C3”.

Summary of Contents for AV-HS60U1P

Page 1: ...This manual is an excerpted version of the Operating Guide For more information please visit the Panasonic website http pro av panasonic net en manual index html and refer to the Operating Guide PDF...

Page 2: ...of the power outlet please consult a qualified electrician WARNING To reduce the risk of fire or electric shock do not expose this equipment to rain or moisture To reduce the risk of fire or electric...

Page 3: ...nt to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generat...

Page 4: ...has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of...

Page 5: ...ly be performed by qualified personnel For continued protection against risk of fire replace only with the same type 3 15 AH 250 V fuse for F1 F2 WARNING This equipment is compliant with Class A of CI...

Page 6: ...se need to be replaced please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse...

Page 7: ...uency applications as connecting cables When connecting to the DVI signal terminal use a cable with a ferrite core If your apparatus is supplied with ferrite core s they must be attached on cable s fo...

Page 8: ...ow to read this document r r Abbreviations The following abbreviations are used in this document f f The model numbers of the Main Frames AV HS60U1P AV HS60U2P AV HS60U1E AV HS60U2E are described as A...

Page 9: ...r and electrical ratings of the unit are indicated on its side panel Installation Refer to the Operating Guide of the AV HS6000 series Accessories f f AC cable AV HS60U1P 1 cable AV HS60U2P 2 cables A...

Page 10: ...es not have the POWER switch for the power supply 2 f f When turning off the power of the redundant power supply model AV HS60U2 set both POWER switches for the power supply 1 and the power supply 2 t...

Page 11: ...put ports GPI IN that control the unit externally and an alarm output port ALARM OUT 11 GPI OUT1 GPI OUT2 terminals connector D sub 25 pin female 2 inch screw signal GPI OUT Equipped with 48 output po...

Page 12: ...4 4 6 4 5 4 7 4 9 4 8 OP STILL1 BUS SHFT 4 SDI IN3 3 SDI IN2 2 SDI IN1 1 Black 12 11 10 SDI IN9 9 SDI IN8 SDI IN11 SDI IN10 8 SDI IN7 7 SDI IN6 6 SDI IN5 5 SDI IN4 Red Red Blue Fig 2 Fig 3 1 Press th...

Page 13: ...ble is used During 3G mode 16 lines f f Connector BNC 16 only the odd numbered terminals can be used f f The even numbered terminals SDI IN 2 SDI IN 4 SDI IN 32 cannot be used f f SDI IN 25 SDI IN 27...

Page 14: ...t from the SDI OUT 13 and SDI OUT 15 terminals f f SDI OUT 13 and SDI OUT 15 terminals are equipped with color correctors The same color corrector setting is also applied to SDI OUT 14 and SDI OUT 16...

Page 15: ...RJ 45 PANEL terminal Compatible with 100Base TX and AUTO MDIX For Control Panel AV HS60C1 AV HS60C2 AV HS60C4 connection f f Connection cable supplied with AV HS60C1 AV HS60C2 AV HS60C4 LAN cable CAT5...

Page 16: ...them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on...

Reviews: