Notification when the power is turned on for the first time

Notification when the power is turned on for the first time

When using the products for the first time, connect the Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4 to the <PANEL> terminal of the Main Frame 
AV-HS60U1/AV-HS60U2, and then turn on the power.
Depending on the combination of the purchased Main Frame and the Control Panel, the version of the firmware for each may not match.
When the version of the firmware for the Main Frame and the Control Panel does not match, the Control Panel will not correctly boot when the power is 
turned on.

Boot status when the versions do not match

Two buttons out of PST/B bus crosspoint buttons in the ME line in front will blink. One button will blink in green, and the other will blink in red. (Fig. 1)

BUS

SHFT

Green

Red

Fig. 1

 

f

When it goes into this status, it is necessary to match the firmware version of the Control Panel to the Main Frame.

 

f

If it does not go into this status and the Control Panel boots normally, the firmware versions of the Main Frame and the Control Panel do match.

 

f

Check the latest software information and perform the version update of the software if necessary. For details, refer to “To perform the version update 
of the software” (page 12).

 

r

To match the firmware version of the Control Panel to the Main Frame

The firmware of the Control Panel is updated when the following operation is performed. Once the update is correctly performed, the firmware version of 
the Control Panel will match with the firmware version of the Main Frame, and it will boot in normal status.

RECALL

STORE

DEL

CHR

LIN

FULL

FULL

WIPE

01s00f

MIX

01s00f

MIX

01s00f

MIX

CG5V

CG6V

CAM1

CAM2

01s00f

MIX

ME2

01s00f

BUS

SHFT

4-1

4-3

4-2

4-4

4-6

4-5

4-7

4-9

4-8

OP

STILL1

BUS

SHFT

4

SDI

IN3

3

SDI

IN2

2

SDI

IN1

1

Black

12

11

10

SDI

IN9

9

SDI

IN8

SDI

IN11

SDI

IN10

8

SDI

IN7

7

SDI

IN6

6

SDI

IN5

5

SDI

IN4

Red

Red

Blue

Fig. 2

Fig. 3

Press the button blinking in red (Fig. 1).

Update of the firmware is started.

 

f

Status when the firmware of the Control Panel is being updated (Fig. 2)
-  Eight buttons out of the PGM/A bus crosspoint buttons in the ME line in front will repeatedly blink in blue from left to right.
-  Eight buttons out of the PST/B bus crosspoint buttons in the ME line in front will blink in red sequentially from left to right.

Update of the firmware will complete after approximately two minutes.

 

f

Status when the update of the firmware of the Control Panel is completed
-  Eight buttons out of the PST/B bus crosspoint buttons in the ME in front will continue to blink in red. (Fig. 3)
-  Depending on the version of the firmware of the Main Frame, the Control Panel may automatically reboot. The firmware of the Control Panel is 

updated correctly for this too.

Turn off the power of the Main Frame and the Control Panel.

 

f

Turn off the power after completing the update of the firmware of the Control Panel.

 

f

Do not turn off the power of the Main Frame and the Control Panel while the firmware of the Control Panel is still updating (Fig. 2).

Turn on the power of the Main Frame and the Control Panel.

Control Panel is booted and the menu screen is displayed in the menu panel when the firmware is correctly updated.

Select the <SYS> button 

 [MAINTENANCE] 

 [Boot] tab 

 [Initial] column 

 [Initial] button.

Select [OK] in the confirmation screen.

The AV-HS6000 is initialized.
Go on to the procedure in “To perform the version update of the software” (page 12).

 

r

To perform the version update of the software

Check the latest software information and perform the version update of the software if necessary.

Check the <SYS> button 

 [MAINTENANCE] 

 [Status] tab 

 [System Version] column 

 [System Version].

Summary of Contents for AV-HS60U1P

Page 1: ...This manual is an excerpted version of the Operating Guide For more information please visit the Panasonic website http pro av panasonic net en manual index html and refer to the Operating Guide PDF...

Page 2: ...of the power outlet please consult a qualified electrician WARNING To reduce the risk of fire or electric shock do not expose this equipment to rain or moisture To reduce the risk of fire or electric...

Page 3: ...nt to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generat...

Page 4: ...has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of...

Page 5: ...ly be performed by qualified personnel For continued protection against risk of fire replace only with the same type 3 15 AH 250 V fuse for F1 F2 WARNING This equipment is compliant with Class A of CI...

Page 6: ...se need to be replaced please ensure that the replacement fuse has a rating of 13 amps and that it is approved by ASTA or BSI to BS1362 Check for the ASTA mark or the BSI mark on the body of the fuse...

Page 7: ...uency applications as connecting cables When connecting to the DVI signal terminal use a cable with a ferrite core If your apparatus is supplied with ferrite core s they must be attached on cable s fo...

Page 8: ...ow to read this document r r Abbreviations The following abbreviations are used in this document f f The model numbers of the Main Frames AV HS60U1P AV HS60U2P AV HS60U1E AV HS60U2E are described as A...

Page 9: ...r and electrical ratings of the unit are indicated on its side panel Installation Refer to the Operating Guide of the AV HS6000 series Accessories f f AC cable AV HS60U1P 1 cable AV HS60U2P 2 cables A...

Page 10: ...es not have the POWER switch for the power supply 2 f f When turning off the power of the redundant power supply model AV HS60U2 set both POWER switches for the power supply 1 and the power supply 2 t...

Page 11: ...put ports GPI IN that control the unit externally and an alarm output port ALARM OUT 11 GPI OUT1 GPI OUT2 terminals connector D sub 25 pin female 2 inch screw signal GPI OUT Equipped with 48 output po...

Page 12: ...4 4 6 4 5 4 7 4 9 4 8 OP STILL1 BUS SHFT 4 SDI IN3 3 SDI IN2 2 SDI IN1 1 Black 12 11 10 SDI IN9 9 SDI IN8 SDI IN11 SDI IN10 8 SDI IN7 7 SDI IN6 6 SDI IN5 5 SDI IN4 Red Red Blue Fig 2 Fig 3 1 Press th...

Page 13: ...ble is used During 3G mode 16 lines f f Connector BNC 16 only the odd numbered terminals can be used f f The even numbered terminals SDI IN 2 SDI IN 4 SDI IN 32 cannot be used f f SDI IN 25 SDI IN 27...

Page 14: ...t from the SDI OUT 13 and SDI OUT 15 terminals f f SDI OUT 13 and SDI OUT 15 terminals are equipped with color correctors The same color corrector setting is also applied to SDI OUT 14 and SDI OUT 16...

Page 15: ...RJ 45 PANEL terminal Compatible with 100Base TX and AUTO MDIX For Control Panel AV HS60C1 AV HS60C2 AV HS60C4 connection f f Connection cable supplied with AV HS60C1 AV HS60C2 AV HS60C4 LAN cable CAT5...

Page 16: ...them to applicable collection points in accordance with your national legislation By disposing of them correctly you will help to save valuable resources and prevent any potential negative effects on...

Reviews: