background image

- 11 -

Connections

Convertible camera:

AW-E350, AW-E650, AW-E655,  
AW-E750, AW-E860, etc.

Viewfinder:

WV-VF65B, AW-VF80, AW-VF64, etc.

Remote control unit (RCU):

WV-RC700A, WV-RC550, AW-RC600, 
etc.

Inter-communications headset
Video monitor

   Use the RCU cable (AW-CA50A6) to 

connect the remote control unit to the 
convertible camera. 
Power to the camera is supplied from the 
remote control unit.

Viewfinder:

WV-VF65B, AW-VF80, 

AW-VF64, etc.

Inter-communications headset

Convertible camera:

AW-E350, AW-E650, AW-E655, 

AW-E750, AW-E860, etc.

Video monitor

Remote control unit (RCU):

 WV-RC700A, WV-RC550,  

AW-RC600, etc.

Composite signals

Coaxial cable

RCU cable:

AW-CA50A6

Inter-communications headset

When configuring a system with the remote control unit

Summary of Contents for AW-PB305AN

Page 1: ...e attempting to connect operate or adjust this product please read these instructions completely Studio Card AW PB305AN This product consists of an studio card and an interface bracket F0806Y1116 D VQTB0134 ...

Page 2: ...igital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operat...

Page 3: ...AND STORE ONLY IN LOCATIONS WHICH ARE NOT EXPOSED TO THE RISK OF DRIPPING OR SPLASHING LIQUIDS AND DO NOT PLACE ANY LIQUID CONTAINERS ON TOP OF THE EQUIPMENT CAUTION TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD AND ANNOYING INTERFERENCE USE THE RECOMMENDED ACCESSORIES ONLY CAUTION TO REDUCE THE RISK OF FIRE OR SHOCK HAZARD REFER CHANGES OF SWITCH SETTINGS INSIDE THE UNIT TO QUALIFIED SERVICE PERSONN...

Page 4: ...ence receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms o...

Page 5: ...amera 10 Mounting the viewfinder on a bracket 10 Connections 11 When configuring a system with the remote control unit 11 When configuring a system with the remote operation panel 12 Setting and changing of menu items 13 Performing the settings 13 Optional card settings submenu 15 Appearance 16 Studio card 16 Interface bracket 17 Specifications 18 Accessories Adjuster plug M6 M3 1 Screws 6 mm 2 Sc...

Page 6: ...interface bracket makes it possible for a viewfinder and or inter communications headset to be used and thus enable the camera to be used as a studio camera Notes The AW PB305A cannot be installed to the following models AW RP605 AW PB605 When the studio card unit is to be discarded at the end of its service life ask a specialized contractor to dispose of it properly in order to protect the enviro...

Page 7: ... the AW VF64 VIDEO ON Outputs images to the viewfinder VIDEO OFF No images appear on the viewfinder The AW VF64 does not come with a standby function 3 Inter communications level control LEVEL This adjusts the sound level output to the inter communications headset 4 Inter communications jack M3 INCOM The inter communications headset is connected here If the plug diameter does not match use the adj...

Page 8: ... connected to the EVF connector 1 on the studio card 8TALLY input connector TALLY IN This is the tally control external input connector OPEN TALLY OFF SHORT TALLY ON When using the AW CB400 remote operation panel and AW CA50T8G control cable for connecting to the convertible camera connect the TALLY cable of the AW CA50T8G to this connector Note Do not connect EVFs to EVF connectors 1 and 2 5 and ...

Page 9: ...the cover 4 Align the studio card with the guides and insert it Ensure the card is fully inserted 5 Firmly tighten the 2 screws 1 4 6 mm to the optional card slot 6 Firmly secure the rear panel with the 4 screws 5 16 8 mm Before installing the studio card Release the static carried in the body of the person to perform the installation Installation can be performed more safely if an anti static wri...

Page 10: ... supplied to the viewfinder onto the top of the interface bracket using the 2 screws provided Mount the base securely so that it is not unsteady 4 Slide the viewfinder onto the mounting base and tighten the fixing knob to secure it firmly 5 Connect the viewfinder cable to the EVF connector 1 or 2 on the interface bracket 6 Connect the EVF cable from the interface bracket to the EVF connector on th...

Page 11: ...nect the remote control unit to the convertible camera Power to the camera is supplied from the remote control unit Viewfinder WV VF65B AW VF80 AW VF64 etc Inter communications headset Convertible camera AW E350 AW E650 AW E655 AW E750 AW E860 etc Video monitor Remote control unit RCU WV RC700A WV RC550 AW RC600 etc Composite signals Coaxial cable RCU cable AW CA50A26 Inter communications headset ...

Page 12: ...an optional accessory for the power supply Inter communication between the remote operation panel and studio card is not possible Viewfinder WV VF65B AW VF80 AW VF64 etc Convertible camera AW E350 AW E650 AW E655 AW E750 AW E860 etc Video monitor Remote operation panel AW CB400 etc Control cable AW CA50T8G TALLY cable AC adapter AW PS505A AC adapter AW PS505A Cable provided with AC adapter 10BASE ...

Page 13: ...s been plugged into the optional card slot of the additional card box The mode selected is displayed here To return to filming mode This is displayed when the convertible camera is used to perform the settings MENU switch ITEM AWC switch YES ABC switch NO BAR switch MENU switch DATA YES UP switch ITEM UP switch ITEM DOWN switch DATA NO DOWN switch Camera settings to match the system configuration ...

Page 14: ...r ITEM AWC switch to move the flashing to the desired setting item then press the YES ABC or NO BAR switch to change the setting When performing the settings with the remote control unit AW RC600 Press the ITME UP or ITEM DOWN switch to move the flashing to the desired setting item then press the DATA YES UP or DATA NO DOWN switch to change the setting 4 Return to filming mode When performing the ...

Page 15: ...e when ON has been selected for the Zebra indicator 1 setting 3Safety zone 1 to 4 OFF This selects the type of safety zone that is displayed in the viewfinder If OFF is selected a safety zone will not be displayed Note The safety zone and the center marker reflect the electrical positions which may differ from the optical positions The inner frame and the outer frame are approximately 90 and 95 re...

Page 16: ... 16 Appearance 3 9 16 91 7 8 21 5 2 3 4 70 Unit inch mm Studio card 3 3 4 96 ...

Page 17: ... 17 7 3 16 183 7 1 2 190 Appearance Unit inch mm Interface bracket 5 9 16 141 1 3 16 30 2 1 16 50 ...

Page 18: ...bracket EVF connector 1 10 pin round composite signals brightness 1 0 V P P EVF connector 2 6 pin round composite signals brightness 1 0 V P P TALLY input connector BNC Switch control functions Studio card EVF standby VIDEO ON OFF switch WV VF65B AW VF80 ST BY ON AW VF64 VIDEO ON VIDEO OFF Inter communications level control Menu screens Zebra indicator ON OFF Level 70 to 110 Safety zone 1 2 3 4 5 ...

Page 19: ... _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 20: ...436 3500 Government Marketing Department 52 West Gude Drive Rockville MD 20850 301 738 3840 Broadcast PARTS INFORMATION ORDERING 9 00 a m 5 00 p m PST 800 334 4881 24 Hr Fax 800 334 4880 Emergency after hour parts orders 800 334 4881 TECHNICAL SUPPORT Emergency 24 Hour Service 800 222 0741 Panasonic Canada Inc 5770 Ambler Drive Mississauga Ontario L4W 2T3 905 624 5010 Panasonic de Mexico S A de C ...

Reviews: